1984
DOI: 10.1016/0142-9612(84)90019-x
|View full text |Cite
|
Sign up to set email alerts
|

Constructional peculiarities of the human tibia defined by reference to ultrasound measurement data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
0

Year Published

1989
1989
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 6 publications
1
11
0
Order By: Relevance
“…Both the mineral-to-collagen ratio and the phosphate-to-carbonate ratio vary by <5% along the mid-shaft but decrease toward the flared extremities of the bone. The changing proportions of mineral and collagen are consistent with gravimetric, mechanical property and density variations, which have been measured in the past, 8,[10][11][12][14][15][16][17][18] but the Raman spectroscopy technique has revealed, for the first time, how complex the adaption is, with bone composition varying over a distance of millimeters.…”
Section: 6 4 Discussionmentioning
confidence: 78%
See 1 more Smart Citation
“…Both the mineral-to-collagen ratio and the phosphate-to-carbonate ratio vary by <5% along the mid-shaft but decrease toward the flared extremities of the bone. The changing proportions of mineral and collagen are consistent with gravimetric, mechanical property and density variations, which have been measured in the past, 8,[10][11][12][14][15][16][17][18] but the Raman spectroscopy technique has revealed, for the first time, how complex the adaption is, with bone composition varying over a distance of millimeters.…”
Section: 6 4 Discussionmentioning
confidence: 78%
“…16 Investigators have also used x-ray tomographic techniques (spatial resolution ∼30 mm) and chemical/gravimetric analysis to show gradients of decreasing bone density toward the distal end of rat femoral diaphyses. 17,18 However, it is not clear from these studies whether the variations in density and stiffness are due to architectural/microstructural differences, due to differing composition of the bone material, or due to both.…”
Section: 12mentioning
confidence: 99%
“…Earlier, in the 1980-90s, a series of studies on bones was conducted by a Latvian group implementing "slow" type waves that they considered as an A0 Lamb or a flexural wave. The velocity was measured by point-contact transducers on short base in order to investigate in detail the long bones as non-uniform biological constructions [19][20][21]. The study has revealed that topographical distribution of the flexural velocity reflects distribution of CT.…”
Section: Introductionmentioning
confidence: 99%
“…Ultrasonic transducers based on the exponential waveguides-concentrators, which were used in the early studies [27]- [31], had numerous advantages. The main advantage was that they served as a point source of acoustic waves, at the frequencies on the order of 100 kHz, providing a sufficiently high amplitude signal necessary for reliable measurement of ultrasound propagation parameters.…”
Section: Ultrasonic Measurements On the Surface Of Long Bones By mentioning
confidence: 99%
“…The studies conducted at LITO with in-house designed ultrasonic devices and transducers, as shown in Fig. 1(a)-(c), were focused on the topography of acoustical properties of long bones [27]- [32]. Most of these studies were conducted using slow propagating guided waves at 100 kHz.…”
mentioning
confidence: 99%