“…We have observed (see also Ref. [27]) that syringes gives typical leakrates ṗa V a = (1 − 100) × 10 −8 mbar × l/s . If we assume p b = 0.1 MPa (atmospheric pressure) and p a ≈ 0 (vacuum) and L y ∕L x = 100 we get from (28…”
Section: Application To Syringe He-gas Leakage Testingmentioning
confidence: 80%
See 1 more Smart Citation
“…We have observed (see also Ref. [27]) that syringes gives typical leakrates ṗa V a = (1 − 100) × 10 −8 mbar × l/s . If we assume p b = 0.1 MPa (atmospheric pressure) and p a ≈ 0 (vacuum) and L y ∕L x = 100 we get from (28…”
Section: Application To Syringe He-gas Leakage Testingmentioning
confidence: 80%
“…The quantity ṗa V a = Ṅa k B T , with units Pa × m 3 ∕s or mbar × l/s , is often measured in He leakage experiments [26][27][28]. Sometimes the leakrate is given as volume of gas at the pressure p b passing through the constriction per unit time.…”
Section: Application To Syringe He-gas Leakage Testingmentioning
confidence: 99%
“…number of ribs), rubber formulation, coating type and area (1,29), additional analysis would be required to understand impact of frictional force on plunger-stopper displacement.. In many cases, more conservative approaches to determine sterility barrier of PFS would result in a lower range of acceptable plunger-stopper displacement.. A previous study performed by Pelaez S et.al. showed that one single plunger rib was adequate to maintain CCI (30). They also investigated tip cap/RNS movement and its impact on CCI of PFS (30) which was outside the scope of this article.…”
Section: Discussionmentioning
confidence: 99%
“…32 Second, the technical characterization of the elastomer-glass interface has long been used for specifying the forces related to the pre-filled syringe sterility barrier and needle exposure. 33 However, the US Food and Drug Administration (FDA) now investigates manufacturers about user-centric design principles in the design and development of new drug delivery devices and recommends specifications based on rigorous usability research rather than technical properties of device components. 34 Third, autoinjector-based treatment options alleviate chronic debilitating conditions associated with cognitive and motor impairments, such as multiple sclerosis, psoriasis, and rheumatoid arthritis.…”
Section: Introductionmentioning
confidence: 99%