2016
DOI: 10.1016/j.nucengdes.2016.03.004
|View full text |Cite
|
Sign up to set email alerts
|

Containment leakage characterization with BARCOM test results for design and over pressure conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 5 publications
1
8
0
Order By: Relevance
“…The milestone of stage III, with regard to the “first appearance of localized crack” was identified, in the discontinuity regions of MAL, EAL, and FMAL, through online monitoring of the inelastic strains using embedded VWSG and other strain gauges and confirmed with soap bubble test. The stage IV experiment is based on the evaluation of ultimate load capacity of BARCOM test model . The structural integrity and health of the containment model were continuously monitored during the over pressure tests at the different over‐pressures through the strain measurement at various El levels.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The milestone of stage III, with regard to the “first appearance of localized crack” was identified, in the discontinuity regions of MAL, EAL, and FMAL, through online monitoring of the inelastic strains using embedded VWSG and other strain gauges and confirmed with soap bubble test. The stage IV experiment is based on the evaluation of ultimate load capacity of BARCOM test model . The structural integrity and health of the containment model were continuously monitored during the over pressure tests at the different over‐pressures through the strain measurement at various El levels.…”
Section: Methodsmentioning
confidence: 99%
“…The present experimental program was organized by the Bhabha Atomic Research Centre (BARC), Trombay, India, for safety assessment of nuclear containment structures in case of the beyond design basis severe accidents. Under this program, an international round robin analysis was organized on BARC Containment (BARCOM) test model . The BARCOM test model of 1:4 size of pre‐stressed concrete inner containment structure of 540 MWe Pressurized Heavy Water Reactor of Tarapur Atomic Power Station Unit 3&4, as shown in Figure , was constructed in BARC experimental facilities at Tarapur.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations