1988
DOI: 10.1016/s0140-6736(88)90695-2
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Arteriovenous Haemodialysis in Critically Ill Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
19
0

Year Published

1990
1990
1998
1998

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(19 citation statements)
references
References 6 publications
0
19
0
Order By: Relevance
“…Since the clearance rates achieved were much greater than those of CAVHF alone, patients with hypercatabolic acute renal fail ure could be managed without the resource to additional conventional haemodialysis treatments [8], In these early reports the direction of the dialysate flow through the dialyzer was countercurrent to the blood flow [7,8], as during conventional machine haemodialysis. Subsequently, reports advo cating the use of CAVHD have either failed to mention the direction of the dialysate flow [9], or have used concurrent flow [10], To determine whether the direction of the dialy sate flow has any effect on the efficiency of CAVHD. we studied 3 patients established on CAVHD.…”
Section: Introductionmentioning
confidence: 99%
“…Since the clearance rates achieved were much greater than those of CAVHF alone, patients with hypercatabolic acute renal fail ure could be managed without the resource to additional conventional haemodialysis treatments [8], In these early reports the direction of the dialysate flow through the dialyzer was countercurrent to the blood flow [7,8], as during conventional machine haemodialysis. Subsequently, reports advo cating the use of CAVHD have either failed to mention the direction of the dialysate flow [9], or have used concurrent flow [10], To determine whether the direction of the dialy sate flow has any effect on the efficiency of CAVHD. we studied 3 patients established on CAVHD.…”
Section: Introductionmentioning
confidence: 99%
“…In practice, the dialysis component (typically with dialysate flow 0.5-2 L/hr) is used for correction of uremia and hyperkalemia, whereas the filtration component is used for net fluid removal [47][48][49]. Earlier reports suggested that the presence of dialpate reduced the transmembrane hydrostatic pressure gradient and consequently the UF rate [2 51.…”
Section: Strctioiz M and Tmentioning
confidence: 99%
“…Treatment modalities included continuous haemofiltration, either arteriovenous [23,26,28-32,37,45,-46,50-53,59], venovenous [36,38,47,49,60,66] or both [34,35,44,55], slow continuous ultrafiltration [6], continuous haemodialysis, either arteriovenous [39,41,54,56,58,61,65,68], venovenous [25,31] or both [9,24,42,62,63], continuous haemodiafiltration [40,48,67,69] as well as both continuous arteriovenous haemofiltration and haemodialysis [43,57] respectively. In one study continuous RRT was combined with intermittent haemodialysis [29].…”
mentioning
confidence: 99%
“…The types of niters used were mostly polyacrylonitrile [9,24,25,28,31,[33][34][35][37][38][39][40][41][42]48,53,58,61,65,66,[68][69][70], but also polysulphone [6,23,26,30,31,36,43,[49][50][51]57] or polyamide [32,44,46,47,51,55,56,58,70] niters have been used. In some studies the type of filter prescribed was not indicated.…”
mentioning
confidence: 99%
See 1 more Smart Citation