2019
DOI: 10.1016/j.ejmp.2019.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Continuous generation of volumetric images during stereotactic body radiation therapy using periodic kV imaging and an external respiratory surrogate

Abstract: We present a technique for continuous generation of volumetric images during SBRT using periodic kV imaging and an external respiratory surrogate signal to drive a patient-specific PCA motion model. Using the on-board imager, kV radiographs are acquired every 3 seconds and used to fit the parameters of a motion model so that it matches observed changes in internal patient anatomy. A multi-dimensional correlation model is established between the motion model parameters and the external surrogate position and ve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 100 publications
0
11
0
Order By: Relevance
“…where 𝜇 x and 𝜇 y are the average CT values in ground truth image and synthesized image respectively, 𝜎 x and 𝜎 y are variance of CT value in ground truth image and synthesized image respectively, and 𝜎 xy is a covariance of ground truth image and synthesized image. C 1 and C 2 were defined as C 1 = (0.01 × L) 2 and C 2 = (0.03 × L) 2 , respectively. L was dynamic range of the image and was defined as the maximum CT value in the ground truth image.…”
Section: Evaluation Of Pca-based Lung Deformation Modelingmentioning
confidence: 99%
See 3 more Smart Citations
“…where 𝜇 x and 𝜇 y are the average CT values in ground truth image and synthesized image respectively, 𝜎 x and 𝜎 y are variance of CT value in ground truth image and synthesized image respectively, and 𝜎 xy is a covariance of ground truth image and synthesized image. C 1 and C 2 were defined as C 1 = (0.01 × L) 2 and C 2 = (0.03 × L) 2 , respectively. L was dynamic range of the image and was defined as the maximum CT value in the ground truth image.…”
Section: Evaluation Of Pca-based Lung Deformation Modelingmentioning
confidence: 99%
“…Some studies regarding volumetric imaging are based on motion modeling with principal component analysis (PCA). In PCA-based motion modeling, [2][3][4]7,9,12,14 internal deformation is represented as a linear combination of the eigenvectors derived by the PCA of the deformation vector field evaluated from patient-specific fourdimensional-computed tomography (4DCT) datasets.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…16 Moreover, marker migration is possible and leads to tumor localization errors. Noninvasive surrogates such as breathing signals from surface imaging can also be used for real-time tumor tracking, [17][18][19][20] but the motion correlation between the external markers and internal target motions may not be perfect 21 and is usually patient-specific. Markerless tracking using online magnetic resonance imaging has been used to track tumors.…”
Section: Introductionmentioning
confidence: 99%