2015
DOI: 10.1016/j.jcin.2015.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Left Atrial Pressure Monitoring During MitraClip

Abstract: a b s t r a c tThe ability of microbes to accelerate chloramine decay to the same degree as under severe nitrification, but without the signs of severe nitrification is reported. Traditionally, only nitrification is believed to microbiologically challenge the stability of chloramine. Chloraminated water containing high amount of natural organic matter (10e12 mg L À1 of dissolved organic carbon (DOC)) was fed to four lab scale reactors connected in series. Each reactor had one day retention time with a total of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
1

Year Published

2017
2017
2018
2018

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 32 publications
(36 citation statements)
references
References 11 publications
0
35
1
Order By: Relevance
“…It is also known that intra‐procedural and inhospital outcomes are better in patients in whom continuous left atrial pressure monitoring is performed when compared to those in whom it is not . Acute changes in mean left atrial pressure are associated with improvement in the 6‐min walk test . There is a gap in the current knowledge base about the relationship if any between 90‐days outcomes (mortality and rehospitalizations) and continuous hemodynamic monitoring during the MitraClip procedure.…”
Section: Discussionmentioning
confidence: 99%
“…It is also known that intra‐procedural and inhospital outcomes are better in patients in whom continuous left atrial pressure monitoring is performed when compared to those in whom it is not . Acute changes in mean left atrial pressure are associated with improvement in the 6‐min walk test . There is a gap in the current knowledge base about the relationship if any between 90‐days outcomes (mortality and rehospitalizations) and continuous hemodynamic monitoring during the MitraClip procedure.…”
Section: Discussionmentioning
confidence: 99%
“…All patients underwent continuous left atrial pressure (LAP) monitoring during TMVR. Briefly, a 4F fluid‐filled multipurpose catheter was inserted into the left atrium alongside the MitraClip steerable guide using previously described methods 11. This allowed for continuous LAP recording throughout the procedure.…”
Section: Methodsmentioning
confidence: 99%
“…Our technique for continuous LAP monitoring has previously been described . Briefly, after transseptal access has been obtained, two stiff J‐tip wires (one 0.032 Amplatz extra‐stiff and one 0.035 Ampltaz super‐stiff) are advanced into the left superior pulmonary vein through an 8F Mullens sheath.…”
Section: Lap Measurementmentioning
confidence: 99%
“…Assessment of acute intraprocedural results is primarily guided by transesophageal echocardiography (TEE), however quantification of MR after a clip is implanted can be challenging due to distortion of mitral valve anatomy and acoustic shadowing by the MitraClip device and delivery catheter . Continuous left atrial pressure (LAP) monitoring has recently emerged as a complementary tool to TEE which can provide real time assessment of the changes in left atrial v wave and mean pressure during the MitraClip procedure, potentially improving procedural results . Changes in left atrial v wave pressure during MitraClip have also been shown to predict clinical improvement in 6 min walk distance at 30 day follow‐up after the procedure .…”
Section: Introductionmentioning
confidence: 99%