2018
DOI: 10.1093/europace/euy038
|View full text |Cite
|
Sign up to set email alerts
|

Continuous monitoring after atrial fibrillation ablation: the LINQ AF study

Abstract: AimsTo study device performance, arrhythmia recurrence characteristics, and methods of outcome assessment using a novel implantable cardiac monitor (ICM) in patients undergoing ablation for atrial fibrillation (AF).Methods and resultsIn 419 consecutive patients undergoing first-time catheter ablation for symptomatic paroxysmal (n = 224) or persistent (n = 195) AF an ICM was injected at the end of the procedure. Telemedicine staff ensured full episode transmission coverage and manually evaluated all automatic a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
47
1
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 58 publications
(52 citation statements)
references
References 21 publications
3
47
1
1
Order By: Relevance
“…As previously mentioned, intermittent monitoring strategies using Holter ECG recordings, for example, tend to underestimate the real AF burden after AF ablation due to a limited recording time . In addition, the assessment of outcome of AF ablation using continuous rhythm monitoring strategies has been influenced by the definition of ablation success …”
Section: Discussionmentioning
confidence: 99%
“…As previously mentioned, intermittent monitoring strategies using Holter ECG recordings, for example, tend to underestimate the real AF burden after AF ablation due to a limited recording time . In addition, the assessment of outcome of AF ablation using continuous rhythm monitoring strategies has been influenced by the definition of ablation success …”
Section: Discussionmentioning
confidence: 99%
“…We included consecutive patients with highly symptomatic AF who underwent consecutive index (1st) and re‐do (2nd) HD‐BVM guided AF ablations at Heart Center Dresden between January 2014 and January 2017. Patients were followed intensively with continuous monitoring as reported previously 8 …”
Section: Methodsmentioning
confidence: 99%
“…Mapping was performed as previously reported 4,8 . In brief, a HD‐BVM map (LVZ <0.5 mV) was created simultaneously with LA surface reconstruction, guided by a three‐dimensional electroanatomical mapping system (CARTO3, Biosense Webster, or Ensite Precision, Abbott) using a circular mapping catheter (Lasso, 4 mm interelectrode spacing, Biosense Webster, or Advisor FL, 3 mm interelectrode spacing, Abbott).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations