Control Automático De Microclima en Invernadero Para Secado Eficiente De Granos De Cacao

Abstract: El propósito del proceso de secado de granos de cacao es conseguir parámetros de humedad aceptables para la comercialización. Para dar respuesta a este requerimiento se implementó un sistema de secado bajo invernadero con ambiente controlado mediante lógica difusa e interfaz de usuario desde un móvil celular. Los resultados obtenidos mostraron la efectividad de la implementación al lograr granos de buena calidad con humedad del ocho (8) % en seis (6) días de secado.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
1
1
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 2 publications
0
2
0
Order By: Relevance
“…Connector "X3" shows the connection of the array of LEDs, which is made up of two channels to which two LEDs are connected in series, and connector number 1 connects the common of the two channels. It should be clarified that figure 4 shows the alternative connection mode "M1" that provides a high current range, but in this project the "M2" configuration is used, which is the low current range, in which channels 1 and 2 are connected to terminals 2 and 3 respectively [18].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Connector "X3" shows the connection of the array of LEDs, which is made up of two channels to which two LEDs are connected in series, and connector number 1 connects the common of the two channels. It should be clarified that figure 4 shows the alternative connection mode "M1" that provides a high current range, but in this project the "M2" configuration is used, which is the low current range, in which channels 1 and 2 are connected to terminals 2 and 3 respectively [18].…”
Section: Methodsmentioning
confidence: 99%
“…The second is BP SOLAR brand: VMP: 16.8VDC; IMP: 1.19AMP. To power the electronic elements, the buoy has a 6 load cell battery that delivers [18].…”