1998
DOI: 10.1109/61.714507
|View full text |Cite
|
Sign up to set email alerts
|

Control design and simulation of unified power flow controller

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
62
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 131 publications
(62 citation statements)
references
References 4 publications
0
62
0
Order By: Relevance
“…PI controllers are conventionally employed for both the tasks while attempting to decouple the d-and q-axiscurrent regulators. In this study, the strategy adopted in [17] for shunt current control has been taken.The inverter current (i p ) is split into real (in phase with acbus voltage) and reactive components. The reference value for the real current is decided so that the capacitor voltage is regulated by power balance.…”
Section: Cascade Control Strategy Of Shunt Convertermentioning
confidence: 99%
See 1 more Smart Citation
“…PI controllers are conventionally employed for both the tasks while attempting to decouple the d-and q-axiscurrent regulators. In this study, the strategy adopted in [17] for shunt current control has been taken.The inverter current (i p ) is split into real (in phase with acbus voltage) and reactive components. The reference value for the real current is decided so that the capacitor voltage is regulated by power balance.…”
Section: Cascade Control Strategy Of Shunt Convertermentioning
confidence: 99%
“…As per the strategy, the original currents in d-q frame (i pd ,i pq ) are now transformed into another frame,d"-q" frame, where d"-axis coincides with the ac-bus voltage (V s ), as shown in Thus, in (d"-q") frame, the currentsi pd" andi pq" represent the real and reactive currents and they are given by : (10) (11) Now, for current control, the same procedure as outlined in [17] has been adopted by re-expressing the above differential equations as: (12) (13)…”
Section: Cascade Control Strategy Of Shunt Convertermentioning
confidence: 99%
“…[4]- [9] The above literature does not deal with the simulink modeling of thirty bus system using UPFC controller. This paper presents modeling and simulation of thirty bus system using matlab/simulink.…”
Section: B Series Invertermentioning
confidence: 99%
“…In this study, the strategy adopted in Refs. [7,8] for shunt current control has been taken. The STATCOM current (i p ) is split into real (in phase with ac-bus voltage) and reactive components.…”
Section: Cascade Control Scheme For Statcommentioning
confidence: 99%
“…In conventional control scheme, there are two voltage regulators designed for these purposes: ac voltage regulator for bus voltage control and dc voltage regulator for capacitor voltage control. In the simplest strategy, both the voltage regulators are proportionalintegral (PI) type cascaded controllers [6,7]. The modeling and control design is usually carried out in the synchronous d Á/q frame, as it is quite standard [8].…”
Section: Introductionmentioning
confidence: 99%