Abstract: -As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Super Capacitor (SC) is able to absorb change of power, and it is examined whether the stable power … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…In case of inverters connected with bidirectional converters, active and reactive currents to be controlled in sequence to control the powers independently and then the inverters can control active and reactive powers at AC sides. Later, PWM with reference values can control the inverter [57]. Another issue with bidirectional power flow with bidirectional converters is the delay during mode transition.…”
Section: Pid Controlmentioning
confidence: 99%
“…In case of inverters connected with bidirectional converters, active and reactive currents to be controlled in sequence to control the powers independently and then the inverters can control active and reactive powers at AC sides. Later, PWM with reference values can control the inverter [57]. Another issue with bidirectional power flow with bidirectional converters is the delay during mode transition.…”
Section: Pid Controlmentioning
confidence: 99%
“…In [57], in order to control the active and reactive power independently, the active and reactive currents are controlled respectively, so that the active and reactive powers for AC side are controlled by the inverter and the inverter is controlled by PWM with the reference values. Simultaneously, the DC bus voltage is tuned by a PI controller and by proposing the power leveling unit, the input and output power is controlled.…”
Section: ) Proportional-integral-derivative (Pid) Controlmentioning
confidence: 99%
“…Nonetheless, the progress of photovoltaic systems has drawn attention to numerous factors that have a direct impact on the performance of this technology [8], [9]. The power converters and storage devices (battery) are the disciplines in which we seek to design and analyze an electrical system ensuring the transfer of power from an energy source to a receiver and guaranteeing the highest possible energy efficiency while limiting losses as much as possible [9], [10]. The power converter is a device composed of electronically controlled switches.…”
Section: Introductionmentioning