2011
DOI: 10.1109/tpel.2010.2070809
|View full text |Cite
|
Sign up to set email alerts
|

Control of Three-Phase PWM Rectifiers Using A Single DC Current Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(13 citation statements)
references
References 12 publications
0
13
0
Order By: Relevance
“…In addition, Figure 4 shows the switching vector in the spatial coordinates of the hexagon. Figure 4 and Table 1 show that the current cannot be measured through the neutral-point shunt resistor during the zero vector (V 0 ) and space vectors represented by Previous research has established the effective voltage time by shifting the pulse width modulation (PWM) or injecting the voltage to restore the current [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24]. However, these methods cause a high total harmonic distortion (THD) by injecting relatively large voltages.…”
Section: Acquiring Phase Current From Neutral Shunt Resistormentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, Figure 4 shows the switching vector in the spatial coordinates of the hexagon. Figure 4 and Table 1 show that the current cannot be measured through the neutral-point shunt resistor during the zero vector (V 0 ) and space vectors represented by Previous research has established the effective voltage time by shifting the pulse width modulation (PWM) or injecting the voltage to restore the current [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24]. However, these methods cause a high total harmonic distortion (THD) by injecting relatively large voltages.…”
Section: Acquiring Phase Current From Neutral Shunt Resistormentioning
confidence: 99%
“…At this time, the measurement line or measurement point is at the boarder of Area 1 or Area 2. Each part of Area 3 has a different type of optimal voltage injection, as shown in Equations (10) and (13)- (23), and in Figure 21.…”
Section: Part 1 D-axismentioning
confidence: 99%
See 1 more Smart Citation
“…In this HCC model, legible losses are produced in AC input source inductance in rectifier-based circuit. In a three phase high power factor HCC PWM converter (Leggate, 1997;Bing et al, 2011). The controller is used here is HCC through which a switching signal is generated.…”
Section: Introductionmentioning
confidence: 99%
“…Sometimes, less current sensors are expected to reduce the total cost of the system. So the current reconstruction technique using single current sensor was proposed [1][2][3][4][5][6][7][8][9][10]. It is not only attractive for low-cost systems, but also useful for fault-tolerant operation of current sensors [11].…”
Section: Introductionmentioning
confidence: 99%