Controlled closing on shunt reactor compensated transmission lines. II. Application of closing control device for high-speed autoreclosing on BC Hydro 500 kV transmission line

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2003
2003
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 5 publications
0
6
0
1
Order By: Relevance
“…At the same time, there was also a desire to avoid mechanical complexity and life-cycle cost associated with maintenance of closing resistors. Over the years, BC Hydro worked with breaker suppliers and adopted Point-On-Wave (POW) control schemes on the lead-end circuit breakers for automatic reclose or manual/supervisory line pick-up [1,2]. These controls, together with surge arresters at the line terminals and also at midline of longer lines, are now being used to improve transmission system insulation performance and reduce stress on the connected equipment.…”
Section: Ii2 Point-on-wave Controlmentioning
confidence: 98%
“…At the same time, there was also a desire to avoid mechanical complexity and life-cycle cost associated with maintenance of closing resistors. Over the years, BC Hydro worked with breaker suppliers and adopted Point-On-Wave (POW) control schemes on the lead-end circuit breakers for automatic reclose or manual/supervisory line pick-up [1,2]. These controls, together with surge arresters at the line terminals and also at midline of longer lines, are now being used to improve transmission system insulation performance and reduce stress on the connected equipment.…”
Section: Ii2 Point-on-wave Controlmentioning
confidence: 98%
“…As shown in Figure 2, the voltage across the contacts of the circuit breaker takes the form of beat. This beat is due to composition among the fundamental frequency of the system from one side of the contact breaker (system side) and the natural frequency of the line and reactors from the other side of the circuit breaker contact (line side) [3,4].…”
Section: Tl Reclosing With Shunt Reactive Compensationmentioning
confidence: 99%
“…The closing instant is determined when the voltage polarities at the source-side and the line-side are identical and when both signals cross by zero. b) Proposed Method (PM) The proposed method [3,4] sends the closing command appropriately such that the poles closing occurs in the first minimum voltage beat across the circuit breaker, after the protection dead time. This method is based on the voltage wave shape across the circuit breaker, independent of voltage zero crossing.…”
Section: Controlled Switchingmentioning
confidence: 99%
“…With the rapid development of global economy, the construction scale of extra high voltage (EHV) long transmission line continues to expand, and the reactive power balance and voltage control become more and more important (Chen, Lee, and Chen 1999;Chuang et al 2010;Froehlich et al 1997;Rahman and Khan 2007). Therefore, people are paying more attention to the manufacture of a controllable reactor that has a wide regulation range, smooth regulation process, fast response and low harmonic content (Alves, Pilotto, and Watanabe 2008;Chen et al 2012;Jin, Goos, and Lopes 1994;Tian et al 2013).…”
Section: Introductionmentioning
confidence: 99%