2015 IEEE Applied Power Electronics Conference and Exposition (APEC) 2015
DOI: 10.1109/apec.2015.7104778
|View full text |Cite
|
Sign up to set email alerts
|

Controller design for TCSC using observed-state feedback method to damp SSR in DFIG-based wind farms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…The function of these two methods is to introduce additional damping into the system. The required damping can be obtained either using SSR damping controller (SSRDC) [35–38, 42–46, 72] or virtual impedance [39]. The typical configuration of a SSRDC is shown in Fig.…”
Section: Sso In Wfs Based On Type 3 Wtgsmentioning
confidence: 99%
See 1 more Smart Citation
“…The function of these two methods is to introduce additional damping into the system. The required damping can be obtained either using SSR damping controller (SSRDC) [35–38, 42–46, 72] or virtual impedance [39]. The typical configuration of a SSRDC is shown in Fig.…”
Section: Sso In Wfs Based On Type 3 Wtgsmentioning
confidence: 99%
“…The TCSC boosts power transfer capability into the transmission line at the fundamental frequency while providing positive resistance to damp SSO at the sub‐synchronous frequencies [41]. SSO damping performance can be further improved using additional SSRDCs as proposed in [72]. A gate‐controlled series capacitor with an additional SSRDC has a similar SSO damping performance such as a TCSC with a SSRDC [42, 43].…”
Section: Sso In Wfs Based On Type 3 Wtgsmentioning
confidence: 99%
“…The damping of different oscillation modes may become worse due to improper parameters, and parameter optimization will become more challenging [11]. As for adding SSO suppression devices, references [12][13][14] proposed to add flexible AC transmission systems (FACTS) such as STATCOM to system to restrain the SSO. In addition, it was proved that a renewable energy hydrogen production system (HPS) can mitigate SSO in [15].…”
Section: Introductionmentioning
confidence: 99%
“…However, the main drawback of these methods is that the SSR frequency is detected after a long time. On the other hand, the SSR phenomenon can be damped using different technologies such as FACTS [25]- [27], supplementary damping controller [28]- [29], passive blocking filter [14], and Kalman filter [30]. Although the damping methods can mitigate SSR, the protection system assure the safety of the network components under any condition.…”
Section: Introductionmentioning
confidence: 99%