Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Objectives: The presence of a catheter required for contrast infusion during sialography obscures imaging of the distal duct. Static imaging via cone beam computed tomography and magnetic resonance sialography fails to address changes that occur dynamically to the anatomy of the flexible salivary ductal system. We aim to identify dynamic changes to the parotid gland by introducing a novel approach to analyze the full extent of Stensen’s duct based on dynamic infusion digital sialography. Methods: Retrospective chart review of a single-center consecutive series of 409 parotid sialograms performed between April 2008 and June 2023 permitted selection of a contemporary series including seven normal sialograms and seven sialograms with stricture(s). Dynamic (fluoroscopic) infusion (iopamidol/gadolinium) sialograms were assessed through blinded review by two radiologists employing the institution’s picture archiving and communication (PACS) system (©2023 Koninklijke Philips N.V., Amsterdam, Netherlands). Measurements determined changes, in two dimensions, to the angle of the masseteric bend and duct length while the catheter was in place (repose), during catheter withdrawal (stretch), and during recoil after withdrawal. Differences in median lengths and angles of Stensen’s duct between the three time points were compared using Wilcoxon matched-pairs signed rank and Mann–Whitney tests. Results: Fourteen patients [median age (IQR), 55 years (24.7); 10 women] were evaluated. The median angle of the masseteric bend was 117.7° in repose versus 155.4° during catheter withdrawal ( P < .001, n = 14). The median distance measured from the Stensen’s duct orifice to the first major ductal bifurcation was 81.5 mm (IQR = 12.3) in repose. The median percent increase in length from repose to stretch was 6.3% ( P < .001, n = 14). Conclusions: Dynamic infusion digital sialography with fluoroscopic recording during catheter removal permits assessment of the distal duct unobstructed by the presence of a catheter. The technique also identifies the dynamic nature and varying length and angulation of Stensen’s duct.
Objectives: The presence of a catheter required for contrast infusion during sialography obscures imaging of the distal duct. Static imaging via cone beam computed tomography and magnetic resonance sialography fails to address changes that occur dynamically to the anatomy of the flexible salivary ductal system. We aim to identify dynamic changes to the parotid gland by introducing a novel approach to analyze the full extent of Stensen’s duct based on dynamic infusion digital sialography. Methods: Retrospective chart review of a single-center consecutive series of 409 parotid sialograms performed between April 2008 and June 2023 permitted selection of a contemporary series including seven normal sialograms and seven sialograms with stricture(s). Dynamic (fluoroscopic) infusion (iopamidol/gadolinium) sialograms were assessed through blinded review by two radiologists employing the institution’s picture archiving and communication (PACS) system (©2023 Koninklijke Philips N.V., Amsterdam, Netherlands). Measurements determined changes, in two dimensions, to the angle of the masseteric bend and duct length while the catheter was in place (repose), during catheter withdrawal (stretch), and during recoil after withdrawal. Differences in median lengths and angles of Stensen’s duct between the three time points were compared using Wilcoxon matched-pairs signed rank and Mann–Whitney tests. Results: Fourteen patients [median age (IQR), 55 years (24.7); 10 women] were evaluated. The median angle of the masseteric bend was 117.7° in repose versus 155.4° during catheter withdrawal ( P < .001, n = 14). The median distance measured from the Stensen’s duct orifice to the first major ductal bifurcation was 81.5 mm (IQR = 12.3) in repose. The median percent increase in length from repose to stretch was 6.3% ( P < .001, n = 14). Conclusions: Dynamic infusion digital sialography with fluoroscopic recording during catheter removal permits assessment of the distal duct unobstructed by the presence of a catheter. The technique also identifies the dynamic nature and varying length and angulation of Stensen’s duct.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.