2021
DOI: 10.1016/j.engstruct.2021.112089
|View full text |Cite
|
Sign up to set email alerts
|

Conventional vs. reinforced resin injected connectors’ behaviour in static, fatigue and creep experiments on slip-resistant steel-FRP joints

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The possible failure modes that can occur in an injected SRR joint under static load can vary. Olivier et al explored them by performing single-lap joint experiments with 60mm hole diameter in the FRP plate and 84mm diameter for the SRR piece [32]. Due to the configuration of the set-up i.e., most of the SRR piece being uncovered, it was possible to distinguish the point in time and the location of the initiation of the different failure mechanisms.…”
Section: Shear Loading Acting On Isrr Connectormentioning
confidence: 99%
See 1 more Smart Citation
“…The possible failure modes that can occur in an injected SRR joint under static load can vary. Olivier et al explored them by performing single-lap joint experiments with 60mm hole diameter in the FRP plate and 84mm diameter for the SRR piece [32]. Due to the configuration of the set-up i.e., most of the SRR piece being uncovered, it was possible to distinguish the point in time and the location of the initiation of the different failure mechanisms.…”
Section: Shear Loading Acting On Isrr Connectormentioning
confidence: 99%
“…The iSRR connector that was previously investigated on steel-concrete composite floor systems has proven to be a possible way to connect also an FRP deck with a steel support structure [30][31][32]. Due to the nature of the FRP, slight modifications of this joining system were introduced.…”
Section: Introductionmentioning
confidence: 99%
“…Injection bolts have also been studied for application in hybrid structures (steel-FRP) for innovative light-weight bridges [8][9][10], in crane girders [11], towers for wind turbines and stadium roofs [7]. Fatigue tests on preloaded injected bolted connections were conducted by several authors showing that there is a contribute to reduce the scatter on the results and to improve the fatigue life [12][13][14][15].…”
Section: Introductionmentioning