2021
DOI: 10.1088/1361-6498/abf94f
|View full text |Cite
|
Sign up to set email alerts
|

Conversion coefficients from absorbed dose to tissue to the newly proposed ICRU/ICRP operational quantities for radiation protection for beta reference radiation qualities

Abstract: The International Commission on Radiation Units and Measurements (ICRU) has, jointly with the International Commission on Radiological Protection (ICRP), recently proposed a set of new operational quantities for radiation protection in ICRU report 95. ICRU/ICRP supplied conversion coefficients for mono-energetic betas but not for beta reference radiation qualities defined by the International Organization for Standardization (ISO) in ISO 6980. Therefore, in this work, conversion coefficients from absorbed dose… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…Focusing on the operational quantities used by the monitoring instrumentation, the ICRU recently presented new definitions in the case of external radiation, improving the methodology for estimating the effective dose and promoting its gradual adoption [ 7 ]. The influence of these novelties must be investigated from the point of view of radiation emergency monitoring: the new operational quantities should allow for a more accurate estimation of the effective dose and dose to the extremities, but relevant differences remain for some photon and neutron fields [ 11 , 12 , 13 ].…”
Section: From Sievert To Graymentioning
confidence: 99%
“…Focusing on the operational quantities used by the monitoring instrumentation, the ICRU recently presented new definitions in the case of external radiation, improving the methodology for estimating the effective dose and promoting its gradual adoption [ 7 ]. The influence of these novelties must be investigated from the point of view of radiation emergency monitoring: the new operational quantities should allow for a more accurate estimation of the effective dose and dose to the extremities, but relevant differences remain for some photon and neutron fields [ 11 , 12 , 13 ].…”
Section: From Sievert To Graymentioning
confidence: 99%
“…However, as these quantities have not yet been internationally adopted in basic safety standards on radiation protection, by bodies such as the International Atomic Energy Agency and the European Commission, they were not adopted in the revised standard series ISO 6980. Anyway, for possible future use, corresponding conversion coefficients have already been determined [48] and are ready for a possible future revision of ISO 6980.…”
Section: Outlook: Quantities According To Icru 95mentioning
confidence: 99%