Cooling water management in European power stations Biology and control of fouling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
71
0
1

Year Published

2001
2001
2016
2016

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 71 publications
(76 citation statements)
references
References 37 publications
1
71
0
1
Order By: Relevance
“…Biofouling of boats in freshwater environments has not received enough attention (Loeb 1986, Jenner et al 1998) but was sufficiently studied in marine environments (Melo and Bott 1997). The current research work is the first report from this part of the world.…”
Section: Resultsmentioning
confidence: 89%
“…Biofouling of boats in freshwater environments has not received enough attention (Loeb 1986, Jenner et al 1998) but was sufficiently studied in marine environments (Melo and Bott 1997). The current research work is the first report from this part of the world.…”
Section: Resultsmentioning
confidence: 89%
“…9). Jenner et al (1998) found that biofouling of cooling water systems by mussels was only significantly reduced when the mean current velocities ranged from 1.8 to 2.2 m s -1 , with a total absence at >2.9 m s -1 .…”
Section: Discussionmentioning
confidence: 99%
“…The present findings, however, showing maintained clearance/feeding rates at current velocities >0.25 m s -1 appear to be generally more consistent with field observations. For example, there is preferential settlement and growth of mussels in areas of high currents, such as mouths of macrotidal estuaries and cooling water systems of electric power plants (Jenner et al 1998). If currents >0.25 m s -1 inhibited feeding, mussels living at Exmouth would only be able to feed for around 11% of the immersion time (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Generally, 0.5 to 2 mg l -1 of chlorine is dosed at the intake area of the cooling systems and the resultant total residual oxidant level ranges from 0.1 to 0.5 mg l -1 (Jenner et al 1998). The most important mechanism for the action of antifoulants is through inactivation of essential enzymes (Chapman 2003, Cross et al 2003, organic constituents in cells (Hassett et al 1999, Chapman 2003, destabilization of cell membranes and cell lysis (Chapman 2003, Walsh et al 2003 and uncoupling the membrane potential (Zhao et al 1998).…”
Section: Introductionmentioning
confidence: 99%