2013
DOI: 10.1016/j.nima.2012.08.023
|View full text |Cite
|
Sign up to set email alerts
|

Coregistration of datasets from a micro-SPECT/CT and a preclinical 1.5T MRI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…Following IV administration, MS-325 binds reversibly to endogenous serum albumin resulting in longer vascular residence time than non-protein binding contrast agents. The binding to serum albumin also increases the magnetic resonance relaxivity and decreases the relaxation time (T1) of water protons in the vicinity (32)(33)(34)(35)(36) resulting in an increase in signal intensity of blood in T1weighted sequences. In human studies, gadofosveset substantially shortened blood T1 values for up to 4 hours after IV bolus injection [24].…”
Section: Vasovist (Ms-325) Ms-325 (Vasovist Bayer Scheringmentioning
confidence: 99%
See 1 more Smart Citation
“…Following IV administration, MS-325 binds reversibly to endogenous serum albumin resulting in longer vascular residence time than non-protein binding contrast agents. The binding to serum albumin also increases the magnetic resonance relaxivity and decreases the relaxation time (T1) of water protons in the vicinity (32)(33)(34)(35)(36) resulting in an increase in signal intensity of blood in T1weighted sequences. In human studies, gadofosveset substantially shortened blood T1 values for up to 4 hours after IV bolus injection [24].…”
Section: Vasovist (Ms-325) Ms-325 (Vasovist Bayer Scheringmentioning
confidence: 99%
“…Nowadays, multimodal preclinical platforms with MRI and SPECT or PET are expanding rapidly. They are designed with separated apparatus [32,33] or combined apparatus [4,5]. In this context, in order to save the use of the tail veins exclusively for radioactive tracer administration for SPECT or PET imaging, the question we seek to answer is whether the SC route could be an alternative to an IV injection during multimodal proceedings involving T1w MRI acquisitions.…”
Section: Tail Puncture In Micementioning
confidence: 99%
“…A common landmark coregistration system consisting of a catheter fixed on a flexible plastic sheet placed between the imaging cell bed and the animal (mouse) was used. 8 As only CT was involved in coregistration, the system was filled with iodine solution. Fiducial markers (n ¼ 8) were positioned manually on the system [ Fig.…”
Section: Multimodal Coregistration Systemmentioning
confidence: 99%
“…[3][4][5] Imaging cells can be shared by different imaging systems, limiting manipulation of animals between the different devices and facilitating multimodal combinations. 3,6,7 The side-by-side configuration 8,9 requires a multimodal compatible imaging cell that can be easily, rigidly, and reproducibly docked on the different imaging devices. It is manually moved from one device to another with acquisitions being performed sequentially.…”
Section: Introductionmentioning
confidence: 99%
“…For the CT unit "Explore CT 120", it is constituted by an X-ray high efficiency tube of 5 kW whose voltage can vary between 70 and 120 kV and is attached to a planar array of CCD detectors 3500 × 2300. The X-ray beam used for the micro-CT unit is conical [2]. Acquisitions can also be done on a micro-PET/CT system with the same protocol because micro-PET and micro-SPECT are both nuclear tomographic imaging techniques with low differences between their principle quality parameters [16].…”
Section: Image Acquisitionsmentioning
confidence: 99%