CoReHA 2.0: A Software Package forIn VivoMREIT Experiments

Abstract: Magnetic resonance electrical impedance tomography (MREIT) is a new medical imaging modality visualizing static conductivity images of electrically conducting subjects. Recently, MREIT has rapidly progressed in its theory, algorithm, and experiment technique and now reached to the stage of in vivo animal experiments. In this paper, we present a software, named CoReHA 2.0 standing for the second version of conductivity reconstructor using harmonic algorithms, to facilitate in vivo MREIT reconstruction of conduc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…We confirmed the quality of reconstructed B z ,1 and B z ,2 images by also performing conductivity reconstruction using the harmonic B z algorithm (Seo et al 2003) via CoReHA 2.0 software(Jeon and Woo 2013). Figure 5 shows the reconstruction results and profile.…”
Section: Resultsmentioning
confidence: 63%
“…We confirmed the quality of reconstructed B z ,1 and B z ,2 images by also performing conductivity reconstruction using the harmonic B z algorithm (Seo et al 2003) via CoReHA 2.0 software(Jeon and Woo 2013). Figure 5 shows the reconstruction results and profile.…”
Section: Resultsmentioning
confidence: 63%
“…CoReHA 2.0 software , a single‐step implementation of the harmonic Bz algorithm , was used to reconstruct relative conductivity distributions. The harmonic Bz algorithm estimates the conductivity distribution σ in a given slice by incorporating the harmonic relationship between the 2D σ and the Laplacian of Bz .…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, harmonic in‐painting of phase data was implemented to replace the data in this area. A ramp‐preserving denoising preprocessing step was also applied to the data to improve the overall SNR. As implemented in CoReHA, the harmonic Bz algorithm is capable of producing only equivalent isotropic‐scaled conductivity images.…”
Section: Methodsmentioning
confidence: 99%
“…Hence CT, PET, SPECT procedures have some disadvantages. Recently, EIT, magnetic resonance electrical impedance tomography (MREIT) [116,126,127,151,167,183,214], magnetic resonance electrical property tomography (MREPT) [222,223,224], Quantitative Susceptibility Mapping (QSM) [141,145,211,212] have been studied for brain imaging.…”
Section: Present Scenario and The Future Trendsmentioning
confidence: 99%