2022
DOI: 10.1097/ico.0000000000003161
|View full text |Cite
|
Sign up to set email alerts
|

Corneal Densitometry to Assess the Corneal Cystine Deposits in Patients With Cystinosis

Abstract: Purpose:The purpose of this study was to assess the suitability of corneal densitometry measurements obtained with Scheimpflug imaging in estimating the corneal changes caused by cystine deposits in the cornea in patients with cystinosis.Methods:Scheimpflug imaging (Pentacam) was performed for 14 patients with cystinosis and 16 age-matched controls. Pentacam data were used for analysis of the corneal densitometry at different zones in the cornea for patients with cystinosis and controls. Densitometry measureme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
4
0

Year Published

2024
2024
2025
2025

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 19 publications
1
4
0
Order By: Relevance
“…17,33,34 Furthermore, the average CD in healthy eyes, measured using AS-OCT, is documented to be 33.4 GSU (converted of a 256-level scale to a 100-level scale). 25 Consistent with expectations and findings of Biswas et al, 18 the CD values of the patients in the current work were higher than the normative mean. However, as shown in Table 2, the obtained CD readings from Pentacam HR in the current work are not of sufficient quality, and corresponding results need to be taken with caution.…”
Section: Discussionsupporting
confidence: 92%
See 4 more Smart Citations
“…17,33,34 Furthermore, the average CD in healthy eyes, measured using AS-OCT, is documented to be 33.4 GSU (converted of a 256-level scale to a 100-level scale). 25 Consistent with expectations and findings of Biswas et al, 18 the CD values of the patients in the current work were higher than the normative mean. However, as shown in Table 2, the obtained CD readings from Pentacam HR in the current work are not of sufficient quality, and corresponding results need to be taken with caution.…”
Section: Discussionsupporting
confidence: 92%
“…Accurate biometric measurements of the anterior segment, including depth of crystal deposition (DCD) and CCT, are essential for the diagnosis of patients with cystinosis and can be used as a parameter for the disease progression and response to treatment. 18 However, the clinician depends on reliable and reproducible measurements for these corneal tomographic parameters. Some previous studies have analyzed CCT and/or DCD using AS-OCT. 30,31 Labbé et al 10 compared these parameters in patients with nephropathic cystinosis, measured by AS-OCT and IVCM.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations