Corneal Evaluation in Healthy Brazilian Children Using a Scheimpflug Topography System

Abstract: Purpose: To identify the distribution and variation in corneal topography, thickness, and elevation in healthy Brazilian children as measured by the Pentacam Scheimpflug system (Oculus Optikgeräte GmbH, Wetzlar, Germany). Methods:Healthy children between 7 and 11 years of age were scanned using the Pentacam Scheimpflug corneal topography system (Oculus Optikgeräte GmbH, Wetzlar, Germany). The exclusion criteria were inability to undergo the ocular exam, history of any ocular diseases (including strabismus, amb… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…This additional analysis reached higher powers for all statistically significant variables (0.88 a 1.0). goals of the present study was to provide translation and validation of this questionnaire in Portuguese language, while following the standard procedures that are already well-defined in the literature (12,13,27) . Following this step, an important tool to screen and follow-up contact lens wearers is now available for incorporation in the clinical practices and researches in countries where Portuguese is the native language.…”
Section: Discussionmentioning
confidence: 99%
“…This additional analysis reached higher powers for all statistically significant variables (0.88 a 1.0). goals of the present study was to provide translation and validation of this questionnaire in Portuguese language, while following the standard procedures that are already well-defined in the literature (12,13,27) . Following this step, an important tool to screen and follow-up contact lens wearers is now available for incorporation in the clinical practices and researches in countries where Portuguese is the native language.…”
Section: Discussionmentioning
confidence: 99%
“…Previous studies have provided substantial information and many normative values for corneal power, astigmatism, corneal thickness, and pachymetric progression indices in adults and healthy children 13 . However, such parameters have not been studied in children with keratoconus or ocular allergy using current tomographers, such as the OCULUS Pentacam Scheimpflug topography system.…”
Section: Discussionmentioning
confidence: 99%
“…Further clinical and technological advances have produced a variety of indices that allow physicians to quantify the severity of corneal irregularity 10 , 11 . Despite the vast amount of studies evaluating corneal parameters in adults 12 and healthy children 13 , similar data on children with corneal irregularities are still scarce 14 . The lack of such information may limit the use of the Scheimpflug technology to identify abnormal corneas earlier in the disease’s progression.…”
Section: Introductionmentioning
confidence: 99%
“…25 Studies that presented normative values of healthy school children using the BAD in Brazil displayed a significant similarity in the main indices. 26,27 In children aged 9.72 ± 0.66 years, BAD D 0.78 ± 0.65, ART max 446.57 ± 81.20, and PPI avg 1.00 ± 0.14 were recorded, 26 while in 7–11-year-old children BAD D 0.80 ± 0.61, ART max 446.42 ± 75.23, and PPI avg 1.00 ± 0.13 were obtained. 27 Normative tomographic values in preschool children were presented by Hashem et al, but for the group of 3–6-year-old and the number of examinees was only 17.…”
Section: Badmentioning
confidence: 98%
“…25 Studies that presented normative values of healthy school children using the BAD in Brazil displayed a significant similarity in the main indices. 26,27 In children aged 9.72 6 0.66 years, BAD D 0.78 6 0.65, ART max 446.57 6 81.20, and PPI avg 1.00 6 0.14 were recorded, 26 while in 7-11-year-old children BAD D 0.80 6 0.61, ART max 446.42 6 75.23, and PPI avg 1.00 6 0.13 were K1, the flattest radius of curvature of the cornea, D; K2, the steepest radius of curvature of the cornea, D; Kmax, point of the highest breaking strength (D); PTL, thickness of the thinnest location on the cornea (pachymetry thinnest location, mm); DATL, distance from the apex of the cornea to the thinnest location on the cornea (distance apex-thinnest location, mm); F. Ele. Th., elevation values for the thinnest point on the cornea for the front surface of the cornea in relation to the reference best-fit sphere (BFS) (mm); B. Ele.…”
Section: Badmentioning
confidence: 99%