1998
DOI: 10.1016/s0002-9394(99)80086-5
|View full text |Cite
|
Sign up to set email alerts
|

Corneal thickness and curvature in normal-tension glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
70
0
21

Year Published

1999
1999
2009
2009

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 138 publications
(91 citation statements)
references
References 12 publications
0
70
0
21
Order By: Relevance
“…Thus, true IOP, and therefore glaucoma risk, may be underestimated in these eyes. This may explain the findings that mean CCT is thinner in patients with normal tension glaucoma compared with those having POAG, 6,7 and thicker in patients with OHT. 8,9 These findings are replicated among different racial groups.…”
Section: Introductionmentioning
confidence: 93%
“…Thus, true IOP, and therefore glaucoma risk, may be underestimated in these eyes. This may explain the findings that mean CCT is thinner in patients with normal tension glaucoma compared with those having POAG, 6,7 and thicker in patients with OHT. 8,9 These findings are replicated among different racial groups.…”
Section: Introductionmentioning
confidence: 93%
“…[4][5][6][7][8][9][10][11] Moreover, many cases of normal-tension glaucoma and ocular hypertension have been erroneously diagnosed by underestimation and overestimation of IOP by GAT in patients whose corneas are thinner or thicker than average, respectively. [12][13][14][15] Dynamic contour tonometry (DCT), a novel digital nonapplanation contact tonometer, has been proposed as an alternative method for obtaining IOP readings significantly closer to true manometric levels. 16 DCT was designed to be largely independent of structural properties of the cornea and to eliminate most of the systematic errors arising from physiological variables of the eye, which render GAT less accurate.…”
Section: Introductionmentioning
confidence: 99%
“…Entretanto, dentre as várias fontes de erro na leitura, a espessura da córnea é um fator físico importante que influencia na rigidez corneana e, então na aferição da Po medida pelo tonômetro de aplanação (4) .…”
Section: Discussionunclassified
“…O tonômetro de aplanação de Goldmann mede a Po registrando a força necessária para achatar o ápice corneano, e baseia-se na lei de Imbert-Fick a qual defende que a superfície corneana é perfeitamente elástica e fina, não oferecendo força adicional alguma à aplanação além da pressão interna do globo ocular (4)(5)(6) . Entretanto ao usar este aparelho estamos sujeitos a alguns erros (3) .…”
Section: Resumo Introduçãounclassified