2021 International Conference on Electrical, Computer and Energy Technologies (ICECET) 2021
DOI: 10.1109/icecet52533.2021.9698754
|View full text |Cite
|
Sign up to set email alerts
|

Corrected Estimation of the Transformer Winding Eddy Losses for Utility-Scale Solar Photovoltaic Plant Application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The load loss values (P cc ) of three-phase distribution transformers can be obtained directly, by applying the IEEE Standard C57.110 [6][7][8][9][10][11][12][13][14][15][16][17] and other well-known standards [18][19][20][21][22][23][24][25][26][27][28][29][30][31][32], or, indirectly, based on their short-circuit resistances referred to as the secondary resistance (R cc ), according to the following expression:…”
Section: Introductionmentioning
confidence: 99%
“…The load loss values (P cc ) of three-phase distribution transformers can be obtained directly, by applying the IEEE Standard C57.110 [6][7][8][9][10][11][12][13][14][15][16][17] and other well-known standards [18][19][20][21][22][23][24][25][26][27][28][29][30][31][32], or, indirectly, based on their short-circuit resistances referred to as the secondary resistance (R cc ), according to the following expression:…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the losses caused by non-sinusoidal currents do not evolve in the same way as those produced by sinusoidal currents. The latter depend on the Root Mean Square (RMS) value of currents, while the losses caused by non-sinusoidal currents also depend on the frequency of the harmonics of these currents [16][17][18][19][20][21][22][23]. The IEEE Standard C57.110-2018 [24,25] establishes that, in the presence of non-sinusoidal currents, the load losses (P LL ) of the transformers are the sum of three others:…”
Section: Introductionmentioning
confidence: 99%
“…In dry-type transformers, as listed in the ANSI/UL Standard 1561-1562 [26,27], Other Stray Losses (P OSL ) are considered to be negligible [19,26,27]. This consideration has also been extended to oil-immersed transformers in papers [16,17,22,28] and transformer manufacturers [29].…”
Section: Introductionmentioning
confidence: 99%