1998
DOI: 10.1007/bf02903590
|View full text |Cite
|
Sign up to set email alerts
|

Correcting an experimental absorption spectrum for the core level width

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…However, to arrive at these values, the contributions from σ y 0 K-edge , σ y 0 mono , and σ y 0 Ph need to be determined [18]. The σ y 0 K-edge derives from the tabulated energy width of the K-edge filter element [19]. The σ y 0 mono can be calculated based on the crystal material, reflection, and photon energy [20].…”
Section: B Source Size and Divergence Measurementsmentioning
confidence: 99%
“…However, to arrive at these values, the contributions from σ y 0 K-edge , σ y 0 mono , and σ y 0 Ph need to be determined [18]. The σ y 0 K-edge derives from the tabulated energy width of the K-edge filter element [19]. The σ y 0 mono can be calculated based on the crystal material, reflection, and photon energy [20].…”
Section: B Source Size and Divergence Measurementsmentioning
confidence: 99%
“…This energy dispersion is spatially mapped on the detector. The measured K-edge width σ edge on the detector contains contributions from the natural energy width of the K edge [35,36] projected to an angular width σ y 0 K-edge , the angular bandwidth of the monochromator crystal [37], σ y 0 mono , and the electron source size σ y . Assuming all contributions are Gaussian shape functions, the electron source size can be obtained by…”
Section: A System Descriptionmentioning
confidence: 99%
“…where ð=ÞðEÞ is the energy-dependent mass-attenuation coefficient around the K-edge of the filter, is the concentration and t is the effective filter thickness. The K-edge spectrum depends on the core-level width, which is normally described by a Lorenz function (Babanov et al, 1998). In this work, to be consistent with the experimental results (Samadi et al, 2015), a Gaussian function is used.…”
Section: Simulation Tools and Methodsmentioning
confidence: 88%
“…Table 1 shows the angular width of the barium K-edge in angle, y 0 K edge , with different crystal reflections. For the same energy edge width ( E K edge = 5.6 eV, or a FWHM of 13.2 eV assuming a Gaussian distribution) (Babanov et al, 1998), a crystal with lower reflection indices is preferred.…”
Section: Figurementioning
confidence: 99%
See 1 more Smart Citation