Correction: Mass-shift mode to quantify low level 129I in environmental samples by ICP-MS/MS

Abstract: Correction for ‘Mass-shift mode to quantify low level 129I in environmental samples by ICP-MS/MS’ by Coralie Carrier et al., J. Anal. At. Spectrom., 2022, 37, 1309–1317, https://doi.org/10.1039/D2JA00128D.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…Then the limit of detection with this method could be 200 times better than that presented in the previous study [40], 11 mBq. The new limit of detection after a chemical treatment could then reach 2 mBq.…”
Section: C) Optimization Of Purification Timementioning
confidence: 59%
See 1 more Smart Citation
“…Then the limit of detection with this method could be 200 times better than that presented in the previous study [40], 11 mBq. The new limit of detection after a chemical treatment could then reach 2 mBq.…”
Section: C) Optimization Of Purification Timementioning
confidence: 59%
“…Na 2 S solution at 0.06 M will be used to eluate iodine from the resin in order to measure 129 I by ICP-MS/MS. b) Improvement of the sensitivity In a previously published work, Tween ® 20 has been used to increase sensitivity and decrease memory effect when measuring iodine by ICP-MS [40].…”
Section: A) Compatibility Between Elution and Icp-ms/ms Measurement M...mentioning
confidence: 99%
“…This result is consistent with recent published research using N 2 O in Agilent 8900 ICP-MS/MS. 21 Authors put forward the bigger size of the N 2 O molecule and the loss of analyte by collision. Accordingly, we used O 2 as a reaction gas and the APEX Ω desolvating module to quantify the 236 U/ 238 U isotope ratios in a certified reference solution and environmental samples.…”
Section: Resultsmentioning
confidence: 99%
“…The initial amount of 127 I is then quantied with an external calibration. 182 The use of 125 I present in certied NIST SRMs 4407H and 4407L is also mentioned to quantify 129 I by ID because the abundance of 129 I in the CRMs is negligible. 183 5.1.2.7.…”
Section: Application For Radionuclide Measurementmentioning
confidence: 99%
“…Recent publications present the possibility of measuring 129 I, a very long-life decay product ( t 1/2 = 1.614 × 10 7 years 181 ), by mass spectrometry in environmental samples with a lower LOD than γ-spectrometry. 182 However, even if its long half-life is favorable for MS measurement, its volatility and the numerous interferences can be challenging. Also, an important memory effect of I in ICP-MS has been reported.…”
Section: Application For Radionuclide Measurementmentioning
confidence: 99%