1995
DOI: 10.1006/jmrb.1995.1082
|View full text |Cite
|
Sign up to set email alerts
|

Correction of Gradient Crosstalk and Optimization of Measurement Parameters in Diffusion MR Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
38
0

Year Published

1999
1999
2004
2004

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(40 citation statements)
references
References 0 publications
2
38
0
Order By: Relevance
“…Quantitative ADC-, T 2 -, and T 1 -maps were calculated by fitting the data to monoexponential models using algorithms (22,23) written in IDL (Research Systems Inc., Boulder, CO). To minimize instrumental errors in the parameter map calculation, extensive data postprocessing, including correction for image-specific background noise and gradient cross-talk correction for the ADC calculation, was performed (22,24).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Quantitative ADC-, T 2 -, and T 1 -maps were calculated by fitting the data to monoexponential models using algorithms (22,23) written in IDL (Research Systems Inc., Boulder, CO). To minimize instrumental errors in the parameter map calculation, extensive data postprocessing, including correction for image-specific background noise and gradient cross-talk correction for the ADC calculation, was performed (22,24).…”
Section: Discussionmentioning
confidence: 99%
“…To minimize instrumental errors in the parameter map calculation, extensive data postprocessing, including correction for image-specific background noise and gradient cross-talk correction for the ADC calculation, was performed (22,24).…”
Section: Discussionmentioning
confidence: 99%
“…To improve temporal resolution, unweighted spin echoes (b 0/0 s/mm 2 ) were recorded intermittently and combined with the subsequently recorded weighted spin echoes (b0/1500 s/mm 2 ). Data postprocessing included correction for image-specific background noise [24]. Calculation of ADC was performed using the monoexponential intravoxel incoherent motion (IVIM) model [25].…”
Section: Nmr Measurementsmentioning
confidence: 99%
“…This interaction between the imaging gradients and diffusion gradients is well known in standard diffusionweighted imaging (DWI) (7)(8)(9) and is generally referred to as "cross-term interaction." If those interactions are not accounted for in the experimental analysis, misinterpretation of the data can easily occur, particularly when the q-space experiments are performed using strong imaging gradients.…”
mentioning
confidence: 99%
“…For standard DWI experiments, Neeman et al (7) and Eis and Hoehn-Berlage (8) solved this problem for unidirectional diffusion measurements, whereas Mattiello et al (9) have done so for diffusion tensor measurements. However, if the q-space technique is to be implemented successfully in conjunction with imaging gradients, the cross-term interactions must also be evaluated for this sequence.…”
mentioning
confidence: 99%