Correction of positioning and angular errors for ball screw feed unit

Abstract: In the present study, we developed a new feed correction mechanism which corrected not only a positioning error (i.e., feed deviation) but also an angular error (i.e., yaw of a table). A correction mechanism including two piezoelectric actuators was constructed and installed between double nuts. The correction mechanism corrects positioning error if both piezoelectric actuators are expanded to the same length, and corrects angular error if one piezoelectric actuator is expanded and the other is contracted. Fir… Show more