Correction of postpneumonectomy syndrome using a custom implant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…The most common long-term complication requiring surgical revision was leakage of the prosthesis (8.9%). Following implant leakage, McRae et al reported the use of a custom-made implant with a wall three times thicker than the initial prosthesis with good results [ 10 ]. Shen et al described a case of re-do thoracotomy at 1 year post-operatively to remove the prosthesis due to symptom recurrence [ 1 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The most common long-term complication requiring surgical revision was leakage of the prosthesis (8.9%). Following implant leakage, McRae et al reported the use of a custom-made implant with a wall three times thicker than the initial prosthesis with good results [ 10 ]. Shen et al described a case of re-do thoracotomy at 1 year post-operatively to remove the prosthesis due to symptom recurrence [ 1 ].…”
Section: Resultsmentioning
confidence: 99%
“…The exposed bronchial stump staple line can be a source of trauma to the prosthesis, resulting in leakage and symptom recurrence [ 24 ]. The use of prophylactic AlloDerm did not protect the implants from trauma [ 10 , 24 ]. McRae et al described the successful use of a custom-made tissue expander with a wall three times as thick as normal implants [ 10 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Conventional prosthetic implants for PPS therapy are silicone breast implants, 2 saline breast implants, and tissue expanders. 3,4 Because of their lack of rigidity, however, these traditional, flexible material prostheses are easily deformed and liable to shift out of position. It is difficult to maintain stable or reliable support in the mediastinum.…”
Section: E136mentioning
confidence: 99%
“…The extrusion of contents also may lead to implant failure. 3 Conventional rigid implants, although not easily deformed, are difficult to fit in the thoracic cavity during surgery. In addition, most of the implants are too heavy.…”
Section: E136mentioning
confidence: 99%