2021
DOI: 10.18280/ti-ijes.652-419
|View full text |Cite
|
Sign up to set email alerts
|

Correction Procedures for Temperature and Irradiance of Photovoltaic Modules: Determination of Series Resistance and Temperature Coefficients by Means of an Indoor Solar Flash Test Device

Abstract: The comparison between I-V (current-voltage) curves measured on site and I-V curves declared by the manufacturer allows to detect decrease of performance and control the degradation of photovoltaic modules and strings. On site, I-V curves are usually obtained under operating conditions (OPCs), i.e. at variable solar radiation and module temperature. OPC curves must be translated into standard test conditions (STCs), at a global irradiance of 1000 W/m2 and a module temperature of 25 °C. The correction at STC co… Show more