Corrections of myocardial tissue sodium concentration measurements in human cardiac 23Na MRI at 7 Tesla

Abstract: Purpose: To quantify the tissue sodium concentration (TSC) in cardiac 23 Na MRI.To evaluate the influence of different correction methods on the measured myocardial TSC. Methods: 23 Na MRI of four healthy subjects was conducted at a whole-body 7T MRI system using an oval-shaped 23 Na birdcage coil. Data acquisition was performed with a density-adapted 3D radial pulse sequence using a golden angle projection scheme. 1 H MRI data were acquired at a 3T MRI system to generate a myocardial mask. Retrospective cardi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
98
2
3

Year Published

2019
2019
2021
2021

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 29 publications
(105 citation statements)
references
References 74 publications
2
98
2
3
Order By: Relevance
“…In previous work concerning quantitative cardiac 23 Na MRI, B 0 correction had only a negligible influence on the measured TSC. 29 The larger influence of the B 0 correction on measured TSC values that was observed in our work might be caused by the relatively high off-resonance values of the reference tubes (mean off-resonance of up to 32 Hz). By contrast, Lott et al 29 used blood as an internal reference, avoiding high susceptibility differences.…”
Section: Discussionmentioning
confidence: 49%
See 1 more Smart Citation
“…In previous work concerning quantitative cardiac 23 Na MRI, B 0 correction had only a negligible influence on the measured TSC. 29 The larger influence of the B 0 correction on measured TSC values that was observed in our work might be caused by the relatively high off-resonance values of the reference tubes (mean off-resonance of up to 32 Hz). By contrast, Lott et al 29 used blood as an internal reference, avoiding high susceptibility differences.…”
Section: Discussionmentioning
confidence: 49%
“…29 The larger influence of the B 0 correction on measured TSC values that was observed in our work might be caused by the relatively high off-resonance values of the reference tubes (mean off-resonance of up to 32 Hz). By contrast, Lott et al 29 used blood as an internal reference, avoiding high susceptibility differences. Here, our B 0 inhomogeneity correction can minimise the distortion in the calibration vials to improve the efficacy of quantification as well as to increase the SNR in the muscles.…”
Section: Discussionmentioning
confidence: 49%
“…Efficient and uniform RF excitation of the heart and kidney is essential for accurately assessing tissue sodium concentration . For the proposed surface RF array, the antenna elements (for both resonant frequencies) are placed close to the cardiorenal targets.…”
Section: Discussionmentioning
confidence: 99%
“…While considerable effort has been applied to the facilitation of quantitative 23 Na MRI through correction of B 0 and B 1 inhomogeneity with field mapping, correction for excitation‐related signal loss requires accurate knowledge of spin‐3/2 relaxation and ω Q values in the tissue of interest. These values may change with pathology and would likely need to be measured in each volunteer.…”
Section: Discussionmentioning
confidence: 99%