“…In order to compare the predicted and calculated vapour pressure behaviour for the components of interest, we decided to use an external check method, based on the Clausius-Clapeyron method, somehow in a similar manner as that of Othmer [32]. Assuming that the logarithm of vapour pressure is linear with respect to the inverse temperature (Clausius-Clapeyron approximation), the behaviour of this property is fully known if one point and the slope are given.…”