Correlation Between Cone-Beam Computed Tomography and High-Resolution Peripheral Computed Tomography for Assessment of Wrist Bone Microstructure

Abstract: High‐resolution peripheral quantitative computed tomography (HR‐pQCT) is considered as the best technique to measure bone microarchitecture in vivo. However, a breakthrough for medical applications is inhibited because of the restricted field of view (∼9 mm) and a relatively long acquisition time (∼3 minutes). The goal of this study was to compare the accuracy of cone‐beam computed tomography (CBCT) and HR‐pQCT and to determine the agreement between CBCT and HR‐pQCT in quantifying bone structural parameters. N… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
15
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 13 publications
1
15
0
Order By: Relevance
“…The bone mass was scanned and analyzed with a micro‐CT system (VivaCT 40; Scanco Medical, Brüttisellen, Switzerland) as previously described in Mys et al . (21). To determine the bone mass indices, including the bone volume:total volume ratio (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), 0.5–5.5 mm below the lowest point of the growth plate was selected as the region of interest, and cross‐sectional images were scanned at 21 μm resolution.…”
Section: Methodsmentioning
confidence: 99%
“…The bone mass was scanned and analyzed with a micro‐CT system (VivaCT 40; Scanco Medical, Brüttisellen, Switzerland) as previously described in Mys et al . (21). To determine the bone mass indices, including the bone volume:total volume ratio (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), 0.5–5.5 mm below the lowest point of the growth plate was selected as the region of interest, and cross‐sectional images were scanned at 21 μm resolution.…”
Section: Methodsmentioning
confidence: 99%
“…Acquisition times can be much faster (<1 min vs. 6 to 9 min) than HR-pQCT due to the larger detector sizes. Improvements to image reconstruction can advance the accuracy of bone microarchitectural measurement to be comparable with HR-pQCT (95,96). Therefore, cone-beam CT could be a viable modality to complement HR-pQCT imaging, thereby increasing access.…”
Section: Disadvantages Of Hr-pqct Scanning and The Limited Field Of Viewmentioning
confidence: 99%
“…Even Scanco does this when it describes the XtremeCT II: "For compatibility with the previous generation HR-pQCT, a XtremeCT I equivalent protocol is available." (5) With this letter, we would also like to take the opportunity to correct the following inaccuracies in our manuscripts: the current of the CBCT was 700 to 1300 μA ( Table 1 in our original publication (2) ); the range of values for XtremeCT was 0 to 200,000 and the threshold was given in permille, and no rescaling was applied to the XtremeCT II values ( Table 2 in our original publication (2) ). Finally, the correct formula for RMSE reads:…”
Section: To the Editormentioning
confidence: 99%
“…
We thank Drs Tran, Vilayphiou, and Koller for their Letter to the Editor (1) commenting on our recent publication (2) in this journal. In their letter, they highlight the need for in vivo imaging of bone microarchitecture.
…”
mentioning
confidence: 99%
See 1 more Smart Citation