Correlation of intracranial pressure and diameter of the sheath of the optic nerve by computed tomography in severe traumatic brain injury

Abstract: We found a correlation between the CT-based ONSD and the median ICP (R=0.32, p<0.05). An ONSD value of 6.35 mm and more is one of the signs of previous or existing ICP.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…Findings from this study add to the growing body of literature on the relationship between ONSD obtained via CT imaging and invasive measures of ICP monitoring and patient outcomes. Previous studies evaluating correlations between CT ONSD values and invasive ICP monitoring have reported modest to strong correlations ( r = 0.32–0.74 47 ). However, previous studies used cross-sectional designs, evaluating a single ONSD measurement from CT with ICP values.…”
Section: Discussionmentioning
confidence: 92%
See 2 more Smart Citations
“…Findings from this study add to the growing body of literature on the relationship between ONSD obtained via CT imaging and invasive measures of ICP monitoring and patient outcomes. Previous studies evaluating correlations between CT ONSD values and invasive ICP monitoring have reported modest to strong correlations ( r = 0.32–0.74 47 ). However, previous studies used cross-sectional designs, evaluating a single ONSD measurement from CT with ICP values.…”
Section: Discussionmentioning
confidence: 92%
“…6 When examining the ability of CT ONSD scores to predict ICP, our study findings were also consistent with previous reports among patients with TBI using a single CT examination. The AUC for ability of ONSD values to predict increased ICP in previous studies ranged from 0.75 to 0.87, 6,7,9 with cutoff values ranging from 5.3 to 6.3. [4][5][6][7]9 However, these studies did not report specific time points for CT measurement.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…High-resolution MRI can be used to measure the ONSD for improved diagnosis of elevated ICP (15,16). A positive correlation was reported between the ONSD and ICP; consequently, the ONSD can be used as a diagnostic indicator of increased ICP (17). The absence of a distinct ONSD cutoff value to identify elevated ICP is primarily due to different examining tools, observers' skill levels, or ONSD fluctuation.…”
Section: Introductionmentioning
confidence: 99%
“…High-resolution MRI can be used as a tool for measuring optic nerve sheath diameter (ONSD) adding in diagnosis of raised intracranial pressure [5,6]. A positive correlation was found between the measurement of optic nerve sheath diameter and the intracranial pressure value, so the optic nerve sheath diameter value can be used as an additional criterion for the diagnosis of increased intracranial pressure [7].…”
Section: Introductionmentioning
confidence: 99%