2022
DOI: 10.4103/ijo.ijo_10_22
|View full text |Cite
|
Sign up to set email alerts
|

Correlation of meiboscale symptom score and sign score for primary meibomian gland dysfunction in Indian eyes – A cross-sectional study

Abstract: Purpose: To evaluate the correlation of Meiboscale with symptom score (Ocular Surface Disease Index [OSDI]) and meibomian gland dysfunction (MGD) sign score. Methods: We performed a cross-sectional hospital-based study of 53 patients of primary MGD who filled the OSDI questionnaire form and underwent complete ocular examination. The MGD sign score was calculated in both eyes using the sum of six grading systems proposed by Arita et al . … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 20 publications
0
1
0
Order By: Relevance
“…45,[48][49][50][51] The Medmont Meridia Professional model uses infrared light to image the MG, and uses an integrated grading scale (Meiboscale) to grade the findings (Figure 14). 27,43,[52][53][54] In addition to the meiboscale, a variety of other grading scales are integrated into the Meridia software system to grade the various captured images (see Figures 9,10 and 14). These provide the capability to grade the meibomian gland images, 43,[52][53][54] assess the degree of MGD (Efron), 19,21 grade conjunctival hyperemia (using both Efron [19][20][21]23 and BHVI scales 20,24 ), record ocular surface staining (corneal via Efron [19][20][21][22][23] and BHVI scales; 20,22,[24][25][26] conjunctival staining via Efron scales [19][20][21][22][23], and finally provide an evaluation of the palpebral conjunctiva (Efron).…”
Section: Dry Eye Assessment Toolsmentioning
confidence: 99%
“…45,[48][49][50][51] The Medmont Meridia Professional model uses infrared light to image the MG, and uses an integrated grading scale (Meiboscale) to grade the findings (Figure 14). 27,43,[52][53][54] In addition to the meiboscale, a variety of other grading scales are integrated into the Meridia software system to grade the various captured images (see Figures 9,10 and 14). These provide the capability to grade the meibomian gland images, 43,[52][53][54] assess the degree of MGD (Efron), 19,21 grade conjunctival hyperemia (using both Efron [19][20][21]23 and BHVI scales 20,24 ), record ocular surface staining (corneal via Efron [19][20][21][22][23] and BHVI scales; 20,22,[24][25][26] conjunctival staining via Efron scales [19][20][21][22][23], and finally provide an evaluation of the palpebral conjunctiva (Efron).…”
Section: Dry Eye Assessment Toolsmentioning
confidence: 99%