2016
DOI: 10.1016/j.surfcoat.2016.08.094
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion and bioactivity evaluation of nanocomposite PCL-forsterite coating applied on 316L stainless steel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
15
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(17 citation statements)
references
References 44 publications
2
15
0
Order By: Relevance
“…The results showed that applying the polymer coating to the anodized AZ91 alloy reduced the wettability angle from 86° ± 1° to 33° ± 1.3°, whereas adding baghdadite nanoparticles increased the wettability angle to 66° ± 1.3 ° in the presence of 5 wt % baghdadite ( Figure 5 and Table 3). Considering the fact that wetting angles between 0 to 90 show a hydrophilic surface [25], it can be concluded that all the specimens have a hydrophilic surface. Although the addition of baghdadite nanoparticles increased the wetting angle, the coating maintained its hydrophilic state in all samples.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The results showed that applying the polymer coating to the anodized AZ91 alloy reduced the wettability angle from 86° ± 1° to 33° ± 1.3°, whereas adding baghdadite nanoparticles increased the wettability angle to 66° ± 1.3 ° in the presence of 5 wt % baghdadite ( Figure 5 and Table 3). Considering the fact that wetting angles between 0 to 90 show a hydrophilic surface [25], it can be concluded that all the specimens have a hydrophilic surface. Although the addition of baghdadite nanoparticles increased the wetting angle, the coating maintained its hydrophilic state in all samples.…”
Section: Resultsmentioning
confidence: 99%
“…One of the polymers that attracted the attention of scientists is polycaprolactone (PCL) due to its high mechanical properties as well as its stability in vivo [23,24]. However, this synthetic polymer has low hydrophobicity and cell affinity, which adversely affect its bonding to surrounding tissue [25]. To address this problem, composites of PCL with bioactive ceramics have been developed to improve cell adhesion and bonding to surrounding tissue.…”
Section: Introductionmentioning
confidence: 99%
“…The wettability test was carried out, using an angle finder, in order to investigate the effect of baghdadite nanoparticles on the hydrophilic or hydrophobic behavior of the applied polymer coating on the AZ91 samples [19]. In each of the tests, a droplet of 2 μL (water) was laid on the surface of the samples, using a DragonLab StepMate stepper (model: JV62782, DragonLab, Beijing, China).…”
Section: Resultsmentioning
confidence: 99%
“…The average wettability angle was reported, using ImageJ software (version 1.52q). In order to examine the surface roughness before and after coating, a Mitutoyo roughness meter (Model: SJ-210, Grainger, Chicago, IL, USA) was used, and the mean surface roughness (Ra) was reported [19,28]. Figure 1a shows the TEM image of the produced baghdadite nanoparticles.…”
Section: Characterization Of Modified and Unmodified Samplesmentioning
confidence: 99%
See 1 more Smart Citation