2021
DOI: 10.5006/3805
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion and Hydrogen Permeation in H2S Environments with O2 Contamination, Part 3: The Impact of Acetate-Buffered Test Solution Chemistry

Abstract: This paper highlights the importance of considering the magnitude of acetate (ethanoate) species concentration on corrosion and hydrogen permeation rates, important factors associated with cracking initiation in steels for sour service qualification. Materials selection relies on standards, such as NACE TM0177 and NACE TM0284, which stipulate that oxygen pollution should be avoided during testing in H2S-containing media. The 5% NaCl test solutions in current standards are buffered using acetic acid (CH3COOH)/s… Show more