Sign up to set email alerts
|

Corrosion behavior of zinc chromate coatings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
2

Year Published

2004
2004
2014
2014

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 2 publications
0
8
0
2
Order By: Relevance
“…Chromate conversion coatings further improve the protection, by enhancing the corrosion resistance, particularly by minimizing the formation of white corrosion products as well as providing a colour finish [2]. Deposition of zinc has been widely investigated using various approaches, which effectively lead to the preparation of coatings that differ in their macro and microstructure, texture, density, uniformity and corrosion resistance [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Chromate conversion coatings further improve the protection, by enhancing the corrosion resistance, particularly by minimizing the formation of white corrosion products as well as providing a colour finish [2]. Deposition of zinc has been widely investigated using various approaches, which effectively lead to the preparation of coatings that differ in their macro and microstructure, texture, density, uniformity and corrosion resistance [3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Then, the total resistance showed a slight decrease but their values were always higher than those corresponding to t = 0. On the other hand, the low impedance values measured at the high frequency range suggest the existence of electrochemical activity in parts of the zinc layer exposed to Na 2 SO 4 solution through defects in the pre-treatment one [18]. This behavior was confirmed by the phase angle evolution towards slightly more capacitive values at the low frequency range, and the displacement of its maximum value towards lower frequencies.…”
Section: Bode Plotsmentioning
confidence: 84%
“…1c depicts that despite having a micro-rough surface and homogenous structure, the ZTRI samples also exhibited the characteristics cracks of chromate layers. According to previous reports [82][83][84] during the drying step of the conversion treatment, the chromium-based layer could shrink due to internal tensile stresses causing micro-cracks or fissures to develop, i.e., make it permeable to the zinc dissolution. This consideration is important because the bare ZHEX and ZTRI samples showed localized corrosion during the exposure to 0.05 M NaCl or 0.1 M SO 4 Na 2 solutions.…”