2017
DOI: 10.1016/j.corsci.2017.02.022
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion behaviour of an assembly between an AA1370 cable and a pure copper connector for car manufacturing applications

Abstract: OATAO is an open access repository that collects the work of Toulouse researchers and makes it freely available over the web where possible. Any correspondence concerning this service should be sent to the repository administrator: staff-oatao@listes-diff.inp-toulouse.fr The corrosion behaviour of an assembly between an AA1370 cable and a pure copper connector for wiring harnesses was studied in neutral chloride and sulphate containing solution. Electrochemical impedance measurements showed that the corrosion … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 44 publications
0
7
0
Order By: Relevance
“…Those two RC circuits correspond to two different kinetic charge transfers. As the literature , suggests, the fast kinetics is the charge transfer in the Gouy–Chapman region. , The slow kinetics is the electron charge transferring across UME surface . In addition, the fact that all spectra have the same time constant values implies that the electrical double layers (EDL) are continuous around the bubble and the substrate.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Those two RC circuits correspond to two different kinetic charge transfers. As the literature , suggests, the fast kinetics is the charge transfer in the Gouy–Chapman region. , The slow kinetics is the electron charge transferring across UME surface . In addition, the fact that all spectra have the same time constant values implies that the electrical double layers (EDL) are continuous around the bubble and the substrate.…”
Section: Resultsmentioning
confidence: 99%
“…31,40 The slow kinetics is the electron charge transferring across UME surface. 41 In addition, the fact that all spectra have the same time constant values implies that the electrical double layers (EDL) are continuous around the bubble and the substrate. The EDL on the bubble contour and the substrate surface should be viewed as the extension of the EDL near the UME, and we can use the same 2-RC equivalent circuit in Figure 4b to model the system.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Studies carried out by other authors between an aluminum cable and a copper connector in a saline environment corroborate the deterioration of aluminum mainly due to galvanic corrosion and crevice corrosion. [ 38,39 ] Furthermore, in Playa Ancha and San Sebastián, which have a higher environmental chloride content, deterioration by corrosion of the copper and CS bolts is clearly observed in zones not covered by aluminum wire.…”
Section: Resultsmentioning
confidence: 99%
“…Overhead Al conductors in long-term service are usually subject to compressive stress at the junction of intermediate Cu transition terminals, which is easy to loose [1][2][3]. It will not only increase the transmission temperature of electrical resistance, but also be vulnerable to acid rain corrosion, and some serious cases may lead to short-circuit fire.…”
Section: Introductionmentioning
confidence: 99%