2000
DOI: 10.1016/s0109-5641(00)00039-7
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion by galvanic coupling between carbon fiber posts and different alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2003
2003
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 28 publications
0
9
0
1
Order By: Relevance
“…16 Furthermore, fiber-reinforced posts do not result in metal corrosion or allergic reactions and can be easily removed from a root canal when failure occurs due to endodontic treatment. 17,18 Due to the increased interest in fiber-reinforced posts in the dental literature, studies have focused on post materials, 19 luting agents, 20 post designs, 21 and ferrule effects to investigate the fracture resistance of these materials. 22 However, those studies produced conflicting results.…”
Section: Introductionmentioning
confidence: 99%
“…16 Furthermore, fiber-reinforced posts do not result in metal corrosion or allergic reactions and can be easily removed from a root canal when failure occurs due to endodontic treatment. 17,18 Due to the increased interest in fiber-reinforced posts in the dental literature, studies have focused on post materials, 19 luting agents, 20 post designs, 21 and ferrule effects to investigate the fracture resistance of these materials. 22 However, those studies produced conflicting results.…”
Section: Introductionmentioning
confidence: 99%
“…5,6,[42][43][44][45][46] These studies examined a number of areas such as the physical properties of the posts and post/root relationship, 6,7,9,[12][13][14]20,22,23,[26][27][28][29][31][32][33]35,37,38,42 retention testing, 11,15,19,22,30,[32][33][34]36,43,44 scanning electron microscopy of the post/root interface, 14,16,17,22,38,40,46,47 microleakage, 10,24 and corrosion of metals with fibre-posts. 18 Other papers examined thermal stress, 41 spectrophotometric analysis, …”
Section: Resultsmentioning
confidence: 99%
“…Fovet et al 18 have shown in galvanic coupling tests between carbon-fibre posts and metals that a corrosion reaction can be set up. This study examined electrochemical behaviour of posts coupled with gold, NiCr and amalgams in an artificial saliva medium.…”
Section: Other In Vitro Investigationsmentioning
confidence: 99%
“…Sin embargo, una investigación de Fovet y colaboradores probó que la misma puede producirse en determinadas circunstancias 26 .…”
Section: Evolución Del Perno Muñónunclassified