Corrosion fatigue analysis of stay cables under combined loads of random traffic and wind

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 46 publications
(7 citation statements)
references
References 35 publications
0
7
0
Order By: Relevance
“…Jiang et al 95 reveal that the combined effects of corrosion and fatigue drastically reduce the lifetime of steel wires, underscoring the insufficient fatigue resistance of stay cables under specific corrosion rates during the service life. Key parameters characterizing steel wire corrosion encompass uniform corrosion depth, maximum corrosion depth, and the decline in mechanical and fatigue properties.…”
Section: Reliability Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Jiang et al 95 reveal that the combined effects of corrosion and fatigue drastically reduce the lifetime of steel wires, underscoring the insufficient fatigue resistance of stay cables under specific corrosion rates during the service life. Key parameters characterizing steel wire corrosion encompass uniform corrosion depth, maximum corrosion depth, and the decline in mechanical and fatigue properties.…”
Section: Reliability Methodsmentioning
confidence: 99%
“…I G U R E 3 4 Time-varying reliability indexes of original and corroded stay cables 93. [Colour figure can be viewed at wileyonlinelibrary.com] T A B L E 3 Uniform corrosion depth parameters 95. Corrosion rateSteel wires inside the stay cable C r…”
mentioning
confidence: 99%
“…For galvanized steel wires, corrosion can be divided into two stages: corrosion of the surface galvanized layer and corrosion of the inner steel wire. Te uniform corrosion depth of each stage can be characterized by an exponential model, as shown in equation ( 19) [34].…”
Section: Steel Wire Time-variant Corrosion Modelmentioning
confidence: 99%
“…Determining each cable's corrosive environment grade and corrosion level for the detail bridge is a challenge relying on technologies and methods selected. Jiang et al [34] set three values for the annual corrosion rate of a high-strength steel wire: 15, 30, and 45 in equation ( 19), corresponding to the low, medium, and high corrosion environment, respectively. Accordingly, the parameters representing the corrosion development trend are set as 0.45, 0.60, and 0.75 in equation (19), respectively, based on the experiment and simulation results of steel wire corrosion [44,45].…”
Section: Fatigue Life Analysis Of Corroded Stay Cablesmentioning
confidence: 99%