2022
DOI: 10.1016/j.molliq.2021.117982
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion inhibition of copper in sulfuric acid via environmentally friendly inhibitor (Myrtus Communis): Combining experimental and theoretical methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 51 publications
(11 citation statements)
references
References 50 publications
0
11
0
Order By: Relevance
“…In addition, generally, the change of corrosion potential can be used to judge as anodic or cathodic corrosion protection when it is greater than the value of 85 mV; otherwise, it is considered to be a hybrid corrosion inhibitor. As observed from Table , the change of corrosion potential values all exceeded 85 mV with changing temperature. Therefore, the PLE is regarded as a cathodic corrosion inhibitor, when it is equal to the soaked times. , η false( % false) = i corr , 0 i corr i corr , 0 × 100 R corr = 0.13 × i × M r d where i corr,0 and i corr are the corrosion current densities when the PLE is present or absent. M r and d respectively represent the relative atomic mass and the density.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, generally, the change of corrosion potential can be used to judge as anodic or cathodic corrosion protection when it is greater than the value of 85 mV; otherwise, it is considered to be a hybrid corrosion inhibitor. As observed from Table , the change of corrosion potential values all exceeded 85 mV with changing temperature. Therefore, the PLE is regarded as a cathodic corrosion inhibitor, when it is equal to the soaked times. , η false( % false) = i corr , 0 i corr i corr , 0 × 100 R corr = 0.13 × i × M r d where i corr,0 and i corr are the corrosion current densities when the PLE is present or absent. M r and d respectively represent the relative atomic mass and the density.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, the PLE is regarded as a cathodic corrosion inhibitor, when it is equal to the soaked times. 68,69 × i i i (%) 100 corr,0 corr corr,0…”
Section: Analysis Of Pdpmentioning
confidence: 99%
“…A high and positive value of Δ N demonstrates that the great capacity of investigated ingredients to donate e- to the cooper surface, especially, the α-pinene molecule. We did not consider the effect of the dipole moments trend μ, on the inhibition performance because there is disagreement on its impact. …”
Section: Discussion and The Results Of The Studymentioning
confidence: 99%
“…Furthermore, the efficacy of essential oils has been investigated across various metal types and corrosive environments. Studies have shown the effectiveness of essential oil to inhibit copper corrosion in 0.5 M HCl, 518,531 aluminium alloy corrosion in 3.5% NaCl, 532 and Cu-Zn alloy corrosion in 3% NaCl. 533 In addition, other biobased compounds such as protein extracts, biodiesels and glycerol have been documented as effective, efficient and environmentally benign inhibitors of metallic corrosion.…”
Section: Green Corrosion Inhibition Using Bio-based Materialsmentioning
confidence: 99%