2013
DOI: 10.1016/j.chroma.2012.11.079
|View full text |Cite
|
Sign up to set email alerts
|

COSMO-RS for the prediction of the retention behavior in micellar liquid chromatography based on partition coefficients of non-dissociated and dissociated solutes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 44 publications
0
12
0
Order By: Relevance
“…In this work, all partition coefficients were measured only once. However, the MLC technique has been established for the determination of partition coefficients of neutral molecules and we used the same method and retention model as described in our previous publications. , Therefore, the maximum error is assumed to be Δlog K i = ± 0.25 in accordance with our previous experiments. The experimentally obtained and calculated partition coefficients in the system TX-114/SDS are shown in Table .…”
Section: Results and Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In this work, all partition coefficients were measured only once. However, the MLC technique has been established for the determination of partition coefficients of neutral molecules and we used the same method and retention model as described in our previous publications. , Therefore, the maximum error is assumed to be Δlog K i = ± 0.25 in accordance with our previous experiments. The experimentally obtained and calculated partition coefficients in the system TX-114/SDS are shown in Table .…”
Section: Results and Discussionmentioning
confidence: 99%
“…Partition coefficients in mixed surfactant systems (an equimolar solution of TX-114/SDS and TX-114/CTAB) were determined using micellar liquid chromatography. In our previous studies, ,, the MLC technique was successfully applied to the determination of partition coefficients in various micelles. Chromatographic analysis was performed with an Agilent 1200 series HPLC.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Similar effects were observed in previous studies. 28,84 According to the protolytic equilibrium at pH = 10.5 the second dissociable functional group (hydroxyl group) of 4-hydroxybenzoic acid and phloretic acid is also dissociated. Because of increasing net charge of the solutes at higher pH, increasing attraction forces between the cationic groups of CTAB and the dissociated molecules are expected.…”
Section: Methodsmentioning
confidence: 99%