Cost-effective reflectance calibration method for small UAV images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 31 publications
0
13
0
Order By: Relevance
“…While the multispectral imagery produced a linear empirical line, an exponential relationship was required for the RGB imagery. An exponential relationship of the empirical line correction for RGB UAV imagery was also identified by Jeong et al ( 2018 ).…”
Section: Methodsmentioning
confidence: 60%
See 2 more Smart Citations
“…While the multispectral imagery produced a linear empirical line, an exponential relationship was required for the RGB imagery. An exponential relationship of the empirical line correction for RGB UAV imagery was also identified by Jeong et al ( 2018 ).…”
Section: Methodsmentioning
confidence: 60%
“…In fact, the use of high-quality field data is imperative for both calibration and validation to standardize UAV-derived outputs suited as model input for prediction of crop parameters (Von Bueren et al, 2014 ). Radiometric correction of imagery is equally important to ensure consistency of optical image data over time and between sites (Jeong et al, 2018 ; Tmusic et al, 2020 ). Hence, despite the large array of UAV image data sets and acquisition and processing routines for crop assessment, potential avenues exist to improve the consistency of diverse data used as input for machine learning approaches.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…These indices were thus sensitive to the camera settings and to the prevailing environmental conditions at the time of the flight. This sensitivity can possibly be reduced by calibration of the sensor signal and conversion to reflectance values using grey reference panels [80]. However, even without this correction, several other VIs were quite robust to the different sensor settings and conditions, and maintained high correlations with the breeder score when data from all observation days were pooled (Figure 4).…”
Section: Research Question 1: Visual-based Indices Are Good Proxies Fmentioning
confidence: 99%
“…Flight altitudes of small UAS (sUAS) typically do not exceed 250 meters due to governmental restrictions on UAS operations [34]. As a result, numerous UAS studies have implemented an empirical line method (ELM) for radiometric calibration of UAS imagery [35,36,[45][46][47][37][38][39][40][41][42][43][44]. The foundation of an ELM is the regression of ground-based spectroradiometer measurements and airborne remotely sensed measurements of a spectrally stable calibration target to develop calibration equations that convert image digital numbers (DNs) to physical at-surface reflectance units [48].…”
Section: Introductionmentioning
confidence: 99%