1994
DOI: 10.1183/09031936.94.07071246
|View full text |Cite
|
Sign up to set email alerts
|

Coughing frequency in patients with persistent cough: assessment using a 24 hour ambulatory recorder

Abstract: C Co ou ug gh hi in ng g f fr re eq qu ue en nc cy y i in n p pa at ti ie en nt ts s w wi it th h p pe er rs si is st te en nt t c co ou ug gh h: : a as ss se es ss sm me en nt t u us si in ng g a a 2 24 4 h ho ou ur r a am mb bu ul la at to or ry y r re ec co or rd de er r ABSTRACT: Cough is an important symptom of many respiratory disorders. We determined the frequency and diurnal variation of cough in normal subjects and in patients with asthma or with persistent cough of unknown cause. We used a portable, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

7
227
3
11

Year Published

1999
1999
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 289 publications
(248 citation statements)
references
References 20 publications
7
227
3
11
Order By: Relevance
“…There was a direct relationship between both airflow and EMG measures of cough intensity and capsaicin concentration. While auditory cough counting score, and the number of expulsive events increased with for each cough priming inspiration and the counted number of "coughs" increased with increasing capsaicin concentration [6][7][8][9], unfortunately the increase in the number of counted coughs does not provide a measure of the intensity of the cough. Thus, the combination of the measurement of airflow pattern and EMG activity allows determination of the expulsive event intensity, and the sum of the expulsion intensities for each priming inspiration provides a measure of the cough intensity.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…There was a direct relationship between both airflow and EMG measures of cough intensity and capsaicin concentration. While auditory cough counting score, and the number of expulsive events increased with for each cough priming inspiration and the counted number of "coughs" increased with increasing capsaicin concentration [6][7][8][9], unfortunately the increase in the number of counted coughs does not provide a measure of the intensity of the cough. Thus, the combination of the measurement of airflow pattern and EMG activity allows determination of the expulsive event intensity, and the sum of the expulsion intensities for each priming inspiration provides a measure of the cough intensity.…”
Section: Discussionmentioning
confidence: 99%
“…The incidence of expulsive events for each cough bout also increased such that there was a greater incidence of CR3, CR4 and CR5 as the concentration of capsaicin increased. The number of expulsive events is one measure of the intensity of a cough [6,7,9].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However the method is labour-intensive and probably impractical in ambulatory conditions. For these reasons automated audiometric methods have been devised [24][25][26]. These are dealt with in detail elsewhere in this Special Issue [27].…”
Section: Frequencymentioning
confidence: 99%