Coupler-Reciprocity System for Hydrophone Calibration at High Pressures

Abstract: A reciprocity system has been developed for the absolute acoustic calibration of small hydrophones at hydrostatic pressures up to 15 000 psi and frequencies to 400 cps. The method involves electrical measurements on three transducers placed in a closed, stiff-walled "coupler" vessel and a measurement of the static acoustic compliance of the coupler. LIST OF SYMBOLSThe three transducers used in the coupler-reciprocity measurement are denoted by the symbols { 1 }, { 2}, and {3}; associated quantities are represe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

1982
1982
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…To correctly obtain the sensitivity of hydrophones in the deep ocean with high hydrostatic pressure, many measurement methods and facilities have been performed all over the world. The most widely used method is the coupler reciprocity method in a low-frequency range below 2 kHz [3][4][5][6]. In addition, the ocean simulation and acoustic calibration vessel were established in the Underwater Sound Reference Division (USRD) [7, IOP Publishing doi:10.1088/1742-6596/2756/1/012044 2 8].…”
Section: Introductionmentioning
confidence: 99%
“…To correctly obtain the sensitivity of hydrophones in the deep ocean with high hydrostatic pressure, many measurement methods and facilities have been performed all over the world. The most widely used method is the coupler reciprocity method in a low-frequency range below 2 kHz [3][4][5][6]. In addition, the ocean simulation and acoustic calibration vessel were established in the Underwater Sound Reference Division (USRD) [7, IOP Publishing doi:10.1088/1742-6596/2756/1/012044 2 8].…”
Section: Introductionmentioning
confidence: 99%
“…As an alternative to free field calibration in an acoustical water tank, a number of different methods for low frequency calibration of hydrophones exist. These include calibration by piezoelectric compensation, 3 acoustic coupler reciprocity calibration 4 and calibration with a pistophone. 5 In the piezoelectric compensation method, the hydrophone is calibrated in an enclosed small water-filled chamber.…”
Section: Introductionmentioning
confidence: 99%
“…Acoustic coupler reciprocity calibration is an absolute calibration method using the reciprocity principle. 4 Though laboratory standard hydrophones may be calibrated with the highest accuracy, the coupler is not a good option to calibrate hydrophones that are large or to calibrate hydrophones near the resonance frequency. In a pistophone, a continuous sound pressure is generated in an enclosed small air-filled chamber by a vibrating piston.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Coupler reciprocity calibrations are historically performed measuring only magnitude [1,3], and [4]. Phase response is more difficult to measure accurately and can be assumed constant when hydrophones are operating well below their resonance frequencies and, for hydrophones with preamplifiers, above their low-frequency cutoff.…”
Section: Introductionmentioning
confidence: 99%