2017 IEEE Power &Amp; Energy Society General Meeting 2017
DOI: 10.1109/pesgm.2017.8274094
|View full text |Cite
|
Sign up to set email alerts
|

Coupling a small battery with a datacenter for frequency regulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…Although many studies have pointed out that datacenters can use workloads to respond flexibly to the requests from the grid, its slow response time severely limits the ability to provide real-time support. Thus, they have to leverage energy storage equipment to cooperate with workload dispatch to provide fast frequency adjustment [23]. For example, Guruprasad et al [23] used the Lyapunov control mechanism in combination with small batteries to adjust energy consumption and, according to the grid demand, to provide real-time grid support.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Although many studies have pointed out that datacenters can use workloads to respond flexibly to the requests from the grid, its slow response time severely limits the ability to provide real-time support. Thus, they have to leverage energy storage equipment to cooperate with workload dispatch to provide fast frequency adjustment [23]. For example, Guruprasad et al [23] used the Lyapunov control mechanism in combination with small batteries to adjust energy consumption and, according to the grid demand, to provide real-time grid support.…”
Section: Related Workmentioning
confidence: 99%
“…Thus, they have to leverage energy storage equipment to cooperate with workload dispatch to provide fast frequency adjustment [23]. For example, Guruprasad et al [23] used the Lyapunov control mechanism in combination with small batteries to adjust energy consumption and, according to the grid demand, to provide real-time grid support. Narayanan et al [22] compared the impact of different energy storage devices on the energy management of datacenters, and illustrated the important role of ESDs in the power consumption control of datacenters.…”
Section: Related Workmentioning
confidence: 99%
“…Only a few of papers studied synergistic strategies that combine IT infrastructure and support loads for FR service. For example, Guruprasa, Murali, Krishnaswamy and Kalyanaraman [48] developed a coupled data center and battery system, which allows data center to work in conjunction with a small battery to provide fast FR service. Li, Brocanelli, Zhang and Wang [49,50] also considered the joint power management of a data center and plug-in electric vehicles for FR service.…”
Section: Synergistic Strategiesmentioning
confidence: 99%