1997
DOI: 10.1016/s0168-583x(96)01007-5
|View full text |Cite
|
Sign up to set email alerts
|

Coupling a total absorption spectrometer to the GSI on-line mass separator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 72 publications
(22 citation statements)
references
References 5 publications
0
22
0
Order By: Relevance
“…The denominator in (10) implies that at Z = 50 the proton occupancy coefficient of the g 9/2 orbit reaches a value of 1.0, and that there is no blocking of the neutron orbit g 7/2 at N = 50. The parameters Z 0 and N 0 were found from the fit to the occupancy coefficients evaluated from the calculation with Model 96C to be…”
Section: Approximation Of the Integral Gt + Strengthmentioning
confidence: 99%
See 1 more Smart Citation
“…The denominator in (10) implies that at Z = 50 the proton occupancy coefficient of the g 9/2 orbit reaches a value of 1.0, and that there is no blocking of the neutron orbit g 7/2 at N = 50. The parameters Z 0 and N 0 were found from the fit to the occupancy coefficients evaluated from the calculation with Model 96C to be…”
Section: Approximation Of the Integral Gt + Strengthmentioning
confidence: 99%
“…Making use of the Total Absorption Spectrometer (TAS) [10], the EC and β + intensity distributions for some nuclides, "southeast" of 100 Sn, including odd and odd-odd ones, have been measured [11][12][13][14][15][16][17][18][19][20]. In particular, the TAS data have supplemented experimental results on β + decay (here and in following we use a denotation β + for both EC and positron emission modes of a decay) that were previously restricted mainly to even-even nuclides.…”
Section: Introductionmentioning
confidence: 99%
“…These isotopes were isolated the OASIS mass separator system [4], collected on a tape transport system, and deposited inside the LBNL Total Absorption Spectrometer (TAS) [5]. TAS consists of a 36×36 cm NaI(Tl) crystal with a 5×20 cm diameter side well plugged by a 4×15 cm NaI(Tl) detector.…”
Section: Methodsmentioning
confidence: 99%
“…For the experimental decay data an effective f t 1/2 can be defined as (5) and is tabulated in Table 1. The effective f t 1/2 values are all <13,000, consistent with |M| 2 >0.5.…”
Section: Shell Modelmentioning
confidence: 99%
“…The characteristics mentioned above were fulfilled by the TAS coupled to the On-line Mass separator at GSI [19,20]. In Fig.…”
Section: The Experimental Techniquementioning
confidence: 99%