2012 IEEE International Symposium on Electromagnetic Compatibility 2012
DOI: 10.1109/isemc.2012.6351760
|View full text |Cite
|
Sign up to set email alerts
|

Coupling interface circuit design for experimental characterization of the narrowband power line communication channel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
5
1
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 9 publications
0
12
0
Order By: Relevance
“…The coupling filter circuit used in China is shown in Figure 2, and its measured transfer function is shown in Figure 3. The coupling filter used in Italy is similar, and it is described in [31]. In both cases the coupling filter acts as a band pass filter, with a 3 dB attenuation in the band between 4 kHz (7 kHz in Italy) and 600 kHz, resulting in a large attenuation of the 50 Hz mains frequency.…”
Section: Measurement Setup In China and Itlaymentioning
confidence: 99%
“…The coupling filter circuit used in China is shown in Figure 2, and its measured transfer function is shown in Figure 3. The coupling filter used in Italy is similar, and it is described in [31]. In both cases the coupling filter acts as a band pass filter, with a 3 dB attenuation in the band between 4 kHz (7 kHz in Italy) and 600 kHz, resulting in a large attenuation of the 50 Hz mains frequency.…”
Section: Measurement Setup In China and Itlaymentioning
confidence: 99%
“…Due to the wide range of values that the impedance at the connector point (access impedance) can assume when the frequency and time vary [49]- [51], it definitely must be brought to the center of discussion when designing a PLC coupler. In fact, the lack of impedance matching may considerably reduce the transmission power [52]- [58] even though impedance matching is ensured within the PCB of the PLC coupler.…”
Section: Impedance Matchingmentioning
confidence: 99%
“…The authors of [83] analyzed the influence of capacitance of an MOV on the insertion loss of a PLC coupler. Although, the capacitance characteristics of an MOV and diodes, such as Zener and high-speed switching diodes [52], may cause distortion in the frequency response (S 12 or S 21 scattering parameter) of PLC couplers, their usage is widely adopted because the cost-benefit is the best available. In order to avoid the disturbing effect of MOVs, GDTs can replace them in PLC couplers designed to operate at frequencies above 35 MHz.…”
Section: F Electric Protectionmentioning
confidence: 99%
See 1 more Smart Citation
“…The coupling filter circuit used in China is shown in Fig.2, and its measured transfer function is shown in Fig.3. The coupling filter used in Italy is similar, and it is described in [30]. In both cases the coupling filter acts as a band pass filter, with a -3dB attenuation in the band between 4 kHz (7 kHz in Italy) and 600 kHz, resulting in a large attenuation of the 50 Hz mains frequency.…”
Section: Measurement Setup In China and Itlaymentioning
confidence: 99%