2020
DOI: 10.1002/sia.6781
|View full text |Cite
|
Sign up to set email alerts
|

Cover Image

Abstract: The cover image is based on the Special Issue Article Optimization of SIMS analytical parameters for water content measurement of olivine by Wan‐Feng Zhang et al., https://doi.org/10.1002/sia.6729.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…The actual sample thickness was determined with a Mitutoyo digital micrometer to be 7480 to 9130 mm, with a measurement uncertainty of 9-10 mm (Table 1). In addition, a set of olivine reference materials for water content was also measured by SIMS, 30 mainly for comparison with the previous analysis procedure.…”
Section: Samples and Preparationmentioning
confidence: 99%
See 2 more Smart Citations
“…The actual sample thickness was determined with a Mitutoyo digital micrometer to be 7480 to 9130 mm, with a measurement uncertainty of 9-10 mm (Table 1). In addition, a set of olivine reference materials for water content was also measured by SIMS, 30 mainly for comparison with the previous analysis procedure.…”
Section: Samples and Preparationmentioning
confidence: 99%
“…These drawbacks of FTIR can potentially be resolved by the increasingly popular secondary ion mass spectrometry (SIMS) technique. 1,3,[23][24][25][26][27][28][29][30][31][32] Major obstacles to accurately measuring ultralow hydrogen samples by SIMS, however, are the relatively high hydrogen background and/or poor detection limit. 1,33,34 To meet this challenge, pioneering improvements include the resin-free mounting technique and vacuum quality enhancement (in the analysis chamber) for the various SIMS models, particularly the CAMECA IMS 3f-7f series and CAMECA Nano-SIMS.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…KLB-1 is a peridotite xenolith with a size of 4-5 cm collected from the Kilborne Hole crater of New Mexico, USA. The detailed description on this sample has been given by Zhang et al 20 Few randomly selected fragments (∼200 mg and ∼1 × 0.5 mm in size) were investigated in this study. They include both darkgreen chrome diopside and pale-brown aluminous opx, and both of them contain very few visible impurities under the microscope.…”
Section: Sample Description and Preparationmentioning
confidence: 99%
“…12 Although un-oriented crystals with one direction polished can also be used when the polarized absorbance is < 0.3 and the mineral is less anisotropic, the analytical accuracy is lower. 13 With the recent development of sample preparation with a Sn-Bi alloy instead of epoxy or indium metal, 14 large geometry secondary ion mass spectrometry (LG-SIMS) has been used to simultaneously measure the water content and oxygen/hydrogen isotopes of ne-grained samples, such as zircon [15][16][17][18][19] and olivine, 20 providing high precision, high spatial resolution and rapid analysis for NAMs.…”
Section: Introductionmentioning
confidence: 99%