2011
DOI: 10.1016/j.arth.2010.07.016
|View full text |Cite
|
Sign up to set email alerts
|

Crack Initiation in Retrieved Cross-Linked Highly Cross-Linked Ultrahigh-Molecular-Weight Polyethylene Acetabular Liners

Abstract: Nine cross-linked UHMWPE acetabular liners were retrieved at revision surgery. Eight of the liners were fully intact and functional at retrieval. Six cases contained shallow initiated cracks at the root of rim notches; one crack had propagated several millimeters. Optical and electron microscopic inspection of the crack surfaces revealed clam shell markings, which are characteristic of fatigue crack initiation. Crack initiation at notches has been identified in reports of catastrophic cross-linked liner failur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
42
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 50 publications
(43 citation statements)
references
References 12 publications
1
42
0
Order By: Relevance
“…The decreased mechanical strength and fatigue resistance remain as concerns [14,15]. Alternatively, stabilization of irradiated UHMWPE with vitamin E has improved strength and toughness [35][36][37][38].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The decreased mechanical strength and fatigue resistance remain as concerns [14,15]. Alternatively, stabilization of irradiated UHMWPE with vitamin E has improved strength and toughness [35][36][37][38].…”
Section: Discussionmentioning
confidence: 99%
“…Postirradiation thermal treatments [8,24,30], ie, annealing below the peak melting point and remelting above the melting point, have been used to reduce the levels of radicals generated during ionizing irradiation that otherwise would induce oxidation and embrittlement. Despite the clinical success of these materials for more than one decade, the decreased mechanical strength and fatigue resistance remain as concerns and may account for reports of early rim fractures of implants [14,15]. Moreover, in vivo oxidation of implants and in vitro oxidation of explants have recently been reported [6,7,28], even for remelted crosslinked UHMWPEs that show excellent oxidative stability during laboratory tests.…”
Section: Introductionmentioning
confidence: 99%
“…Although polyethylene wear and aseptic loosening were important reasons for failure of CPE inserts, these were not seen with the XLPE inserts (Table 2). We found no evidence of an increased propensity for rim fracturing or cracking with the XLPE liners, which has been reported in some previous studies [16,17,35]. We also specifically evaluated the damage scores in the peripheral zone of the liner that contacts with the locking mechanism in the shell.…”
Section: Discussionmentioning
confidence: 52%
“…While reports of clinical fracture or crack-related failures remain rare for crosslinked UHMWPE implants, clinically retrieved components have been reported involving catastrophically fractured bearings [4,15], intact components containing initiated subcritical cracks [6], and bearing surfaces exhibiting extensive apparently brittle surface cracking [5]. Crosslinked formulations of UHMWPE provide an excellent wear-resistant bearing surface in total joint arthroplasty, but the long-term resistance to crack-related damage phenomena in these materials is unclear.…”
Section: Introductionmentioning
confidence: 99%
“…A relative decrease in K incep generally shifts the stable crack propagation uniformly to lower values of stress intensity [3,8,12], and such a shift is known to accompany crosslinking in UHMWPE [3,8,12]. The reduced toughness and crack propagation resistance of crosslinked formulations of UHMWPE are of interest for clinical applications, particularly in light of recently reported cases of brittle damage or catastrophic fracture of highly crosslinked THA bearings [4][5][6]15].…”
Section: Introductionmentioning
confidence: 99%